radial head prosthesis removal:a retrospective case series of 14 patients
Authors
abstract
background: the purpose of this study was to report the preoperative complaints and postoperative outcome of patients after removal of the radial head prosthesis. methods: this is a retrospective review of 14 adult patients (6 females and 8 males) from 2007 to 2011, who underwent radial head prosthesis removal by three surgeons. the average time between implantation and removal was 23 months (range from 2 weeks to 12 years, median 12 months). results: the leading reported complaints before removal were restricted mobility of the elbow (active range of motion of less than 100 degrees) in 6, pain in 3, and pain together with restricted mobility in 4 patients. the objective findings before removal were restricted mobility of the elbow in 10 (71%), capitellar cartilage wear, loose implants, and heterotopic ossification each in 8 (57%), subluxation of the radio-capitellar joint or malpositioning of the stem in 5 (36%), and chronic infection in 2 (14%) patients. all patients with pain had wear of the capitellar cartilage on radiographs. the ulnar nerve was decompressed in four patients at the time of removal. four patients underwent a subsequent operation for postoperative ulnar nerve symptoms 5 to 21 months after removal. four patients were still complaining about persistent pain at the last follow-up visit. except two patients, the total range of motion improved with a mean of 34 degrees (range 5 to 70) after a mean follow-up of 11 months. conclusions: removal of radial head prosthesis improved function and lessened pain in our case series. the reoperation rate was yet nearly 30% due to ulnar neuritis. selective ulnar nerve decompression at the time of removal must be evaluated, especially in patients with expected large gain in range of motion after removal.
similar resources
Radial Head Prosthesis Removal:a Retrospective Case Series of 14 Patients
Background: The purpose of this study was to report the preoperative complaints and postoperative outcome of patients after removal of the radial head prosthesis. Methods: This is a retrospective review of 14 adult patients (6 females and 8 males) from 2007 to 2011, who underwent radial head prosthesis removal by three surgeons. The average time between implantation and removal was 23 month...
full textRadial Head Prosthesis Removal: a Retrospective Case Series of 14 Patients
BACKGROUND The purpose of this study was to report the preoperative complaints and postoperative outcome of patients after removal of the radial head prosthesis. METHODS This is a retrospective review of 14 adult patients (6 females and 8 males) from 2007 to 2011, who underwent radial head prosthesis removal by three surgeons. The average time between implantation and removal was 23 months (r...
full textRadial head prosthesis: results overview
BACKGROUND/PURPOSE Radial head replacement is frequently used in treatment of radial head fractures or sequela. Impossibility to restore a correct anatomy, acute elbow traumatic instability and failure of osteosynthesis hardware are the most common indications. The authors describe their case studies and results on the implantation of various radial head prostheses. MATERIALS Between June 200...
full textHydrocephalus in Patients With Head Trauma: A Series of 14 Patients
Background and Aim: Hydrocephalus can cause ventricular expansion, which if not treated promptly, can result in brain damage. The hydrocephalus-induced damage is not fully improved, even by means of surgical procedures, leading to permanent damages to the brain. Methods and Materials/Patients: The aim of this study was to evaluate the demographic characteristics as well as hydrocephalus in pat...
full textHistory of radial head prosthesis in traumatology.
A review of the literature was performed to survey the history of the radial head prosthesis in traumatology. Radial head resection was the treatment of choice before Speed first reconstructed the radial head with a metal prosthesis. Over the years, the indication for the use of a radial head prosthesis changed from the prevention of heterotopic ossification to the prevention of proximal migrat...
full textA floating prosthesis for radial-head fractures.
We report our experience over seven years with a floating radial-head prosthesis for acute fractures of the radial head and the complications which may result from such injury. The prosthesis has an integrated articulation which allows change of position during movement of the elbow. We present the results in 12 patients with a minimum follow-up of two years. Five prostheses had been implanted ...
full textMy Resources
Save resource for easier access later
Journal title:
the archives of bone and joint surgeryجلد ۳، شماره ۲، صفحات ۸۸-۹۳
Keywords