evaluation of distal femoral rotational alignment with spiral ct scan before total knee arthroplasty (a study in iranian population)

Authors

mahmoud jabalameli shafa orthopedic hospital, iran university of medical sciences, tehran, iran

amin moradi tabriz shohada hospital, tabriz university of medical sciences, tabriz, iran

abolfazl bagherifard shafa orthopedic hospital, iran university of medical sciences, tehran, iran

mehran radi shafa orthopedic hospital, iran university of medical sciences, tehran, iran

abstract

background: evaluating the landmarks for rotation of the distal femur is a challenge for orthopedic surgeons. although the posterior femoral condyle axis is a good landmark for surgeons, the surgical transepicondylar axis may be a better option with the help of preoperative ct scanning. the purpose of this study was to ascertain relationships among the axes’ guiding distal femur rotational alignment in preoperative ct scans of iranian patients who were candidates for total knee arthroplasty and the effects of age, gender, and knee alignment on these relationships. methods: one hundred and eight cases who were admitted to two university hospitals for total knee arthroplasty were included in this study. the rotation of the distal femur was evaluated using single axial ct images through the femoral epicondyle. four lines were drawn digitally in this view: anatomical and surgical transepicondylar axes, posterior condylar axis and the whiteside anteroposterior line. the alignment of the extremity was evaluated in the standing alignment view. then the angles were measured along these lines and their relationship was evaluated. results: the mean angle between the anatomical transepicondylar axis and posterior condylar axis and between the surgical transepicondylar axis and posterior condylar axis were 5.9 ± 1.6 degrees and 1.6±1.7 degrees respectively. the mean angle between the whiteside’s anteroposterior line and the line perpendicular to the posterior condylar axis was 3.7±2.1 degrees. significant differences existed between the two genders in these relationships. no significant correlation between the age of patients and angles of the distal femur was detected. the anatomical surgical transepicondylar axis was in 4.3 degrees external rotation in relation to the surgical transepicondylar axis. conclusion: preoperative ct scanning can help accurately determine rotational landmarks of the distal femur. if one of the reference axes cannot be determined, other reference axes can be used because of the good correlation between these landmarks.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Evaluation of Distal Femoral Rotational Alignment with Spiral CT Scan before Total Knee Arthroplasty (A Study in Iranian Population)

    Background: Evaluating the landmarks for rotation of the distal femur is a challenge for orthopedic surgeons. Although the posterior femoral condyle axis is a good landmark for surgeons, the surgical transepicondylar axis may be a better option with the help of preoperative CT scanning. The purpose of this study was to ascertain relationships among the axes’ guiding distal femur rotational ...

full text

Evaluation of Distal Femoral Rotational Alignment with Spiral CT Scan before Total Knee Arthroplasty (A Study in Iranian population).

BACKGROUND Evaluating the landmarks for rotation of the distal femur is a challenge for orthopedic surgeons. Although the posterior femoral condyle axis is a good landmark for surgeons, the surgical transepicondylar axis may be a better option with the help of preoperative CT scanning. The purpose of this study was to ascertain relationships among the axes' guiding distal femur rotational align...

full text

The variability of femoral rotational alignment in total knee arthroplasty.

BACKGROUND Several reference axes are used to establish femoral rotational alignment during total knee arthroplasty, but debate continues with regard to which axis is most accurately and easily identified during surgery. Computer-assisted navigation systems have been developed in an attempt to more accurately and consistently align implants during total knee arthroplasty, but it is unknown if n...

full text

Anthropometric Measurements of Distal Femur to Design the Femoral Component of Total Knee Arthroplasty for the Iranian Population

Background: Acquiring knowledge about anatomic and geometric quantities of bones is among the most vitalparameters in orthopedic surgery that has a significant effect on the treatment of various disorders and subsequentoutcomes. The aim of this study was to obtain anthropometric information for distal femur in order to compare withsimilar dimensions of prosthesis used in total...

full text

A clinical study of the rotational alignment of the femoral component in total knee arthroplasty

We describe here various surgical options to obtain a correct rotational alignment of femoral component in total knee arthroplasty (TKA). The correct rotational alignment is the key point to obtain a rectangular balanced flexion gap as well to have a good patellar tracking. For that reason, rotation alignment largely affects postoperative kinematic results particularly during flexion.