solid phase extraction of trace copper in aqueous samples using c18 membrane disks modified by benzildithiosemicarbazone prior to flame atomic absorption spectrometric (faas) determination
Authors
abstract
a highly convenient, selective and sensitive procedure for pre-concentration, separation and determination of sub-ppm levels of cu 2+ in aqueous samples based on modification of octadecyl silica bonded phase membrane (osbpm) disks is described using benzildithiosemicarbazone (bdsc) as a powerful modifier. it was revealed that each loaded osbpm disk with 6.0 mg of bdsc serves as excellent bead for trapping, enrichment and isolation of trace copper. the analyte was trapped during introduction the aqueous solutions through the surface of each modified membrane, quantitatively, while other interfering ions passed through the disk to drain. the adsorbed cu 2+ ions were then stripped by appropriate eluting agents followed by monitoring of the eluates by faas. the effects of sample ph, amount of the modifier, stripping agent types and sample flow-rates were also investigated. the described method permitted a pre-concentration factor of about 200. the detection limit of the procedure was predicted to be about 0.013 ng l -1 . the method was successfully employed for recovery and quantification of trace copper in different water samples.
similar resources
Cold Vapor Atomic Absorption Determination of Hg in Crude Oil and Gasoline Samples after Solid Phase Extraction Using Modified Disks
A facile and highly efficient method have been developed for the preconcentration of the mercury content in crude oil and gasoline samples after digestion with microwave-assisted digestion. Octadecyl silica membrane disk has been modified by the recently synthesized triazene ligand, (E)-1-(2-ethoxyphenyl)-3-(4-nitrophenyl) triaz-1-ene (ENT), then the modified membrane was used for the preco...
full textDetermination of Trace Copper(II) in Food Samples by Flame Atomic Absorption Spectrometry after Cloud Point Extraction
A new method for the determination of trace copper(II) in food samples by Cloud Point Extraction(CPE) combined with Flame Atomic Absorption Spectrometry(FAAS) is presented and evaluated. The method is based on the fact that hydrophobic complex of copper(II) with sodium diethyldithiocarbamate (DDTC) was formed at pH 6.0 and subsequently the hydrophobic complex was extracted into surfactant-r...
full textDetermination of lead and cadmium in water samples by cloud point extraction prior to flame atomic absorption spectrometry determination
Pb and Cd in water samples were determined by cloud point extraction (CPE) with sodiumdiethyldithiocarbamate (DDTC) as the chelating agent and octylphenoxypolyethanl (Triton X-114) asthe surfactant prior to flame atomic absorption spectrometry (FAAS) determination. The main factorsof affecting the extraction and detection processes were optimized. The preconcentration of 10 mL ofstandard soluti...
full textcold vapor atomic absorption determination of hg in crude oil and gasoline samples after solid phase extraction using modified disks
a facile and highly efficient method have been developed for the preconcentration of the mercury content in crude oil and gasoline samples after digestion with microwave-assisted digestion. octadecyl silica membrane disk has been modified by the recently synthesized triazene ligand, (e)-1-(2-ethoxyphenyl)-3-(4-nitrophenyl) triaz-1-ene (ent), then the modified membrane was used for the preconcen...
full textComparison of Modified Palladium Nanoparticles and Homemade Activated Carbon Derived from Medlar for Solid Phase Extraction of Metal Ions Prior to Their Flame Atomic Absorption Spectrometry Determination
This study focus on the preparation of two supports including activated carbon derived from medlar and Palladium nanoparticles loaded on activated carbon (Pd-NP-AC). Subsequently, both adsorbent modified with a novel Schiff base chelating agent and their potential applicability for determination of trace amounts of metal ions from aqueous solution has been investigated. The method is based on c...
full textdetermination of trace copper(ii) in food samples by flame atomic absorption spectrometry after cloud point extraction
a new method for the determination of trace copper(ii) in food samples by cloud point extraction(cpe) combined with flame atomic absorption spectrometry(faas) is presented and evaluated. the method is based on the fact that hydrophobic complex of copper(ii) with sodium diethyldithiocarbamate (ddtc) was formed at ph 6.0 and subsequently the hydrophobic complex was extracted into surfactant-rich ...
full textMy Resources
Save resource for easier access later
Journal title:
journal of chemical health risksجلد ۳، شماره ۲، صفحات ۰-۰
Hosted on Doprax cloud platform doprax.com
copyright © 2015-2023