better hemodynamic profile of laryngeal mask airway insertion compared to laryngoscopy and tracheal intubation

Authors

hashem jarineshin anesthesiology, critical care and pain management research center, hormozgan university of medical sciences, bandar abbas, ir iran

saeed kashani anesthesiology, critical care and pain management research center, hormozgan university of medical sciences, bandar abbas, ir iran

majid vatankhah anesthesiology, critical care and pain management research center, hormozgan university of medical sciences, bandar abbas, ir iran

alireza abdulahzade baghaee anesthesiology, critical care and pain management research center, hormozgan university of medical sciences, bandar abbas, ir iran

abstract

results participants in all groups were similar in terms of gender, age, weight, height, and mallampati class. the mean ± sd of sbps (105.62 ± 12.12, 112.90 ± 12.2, and 112.48 ± 15.14 mm hg, respectively for ett, lma-c, and lma-s) and dbps (64.64 ± 10.23, 73.78 ± 9.70, and 71.20 ± 12.27 mm hg, respectively for ett, lma-c, and lma-s) were significantly lower in the ett group compared to lma groups 5 minutes after device insertion (p < 0.01 for sbps and p < 0.001 for dbps); however these values were lower than the baseline values in all groups. there were no differences in the mean sbp and dbps between the three groups at the other time points. the mean ± sd heart rates in the ett group, compared to the lma-c and lma-s groups, were considerably higher in the first minute (100.06 ± 18.27, 82.50 ± 10.52, and 82.00 ± 13.60 bpm, respectively for ett, lma-c, and lma-s), third minute (91.04 ± 17.12, 78.84 ± 11.23, and 78.90 ± 13.41 bpm, respectively for ett, lma-c, and lma-s) and fifth minute (85.82 ± 16.01, 75.78 ± 11.73, and 75.04 ± 13.90 bpm, respectively for ett, lma-c, and lma-s) after intubation (p < 0.001). there were no significant differences between the lma-c and lma-s groups in terms of hemodynamic parameters. conclusions maintaining the airway using laryngeal mask airway is associated with less cardiovascular responses compared to direct laryngoscopy and tracheal intubation. background laryngoscopy and tracheal intubation can cause serious cardiovascular responses in patients such as hypertension, tachycardia, and arrhythmias. alternative airway maintenance techniques may attenuate these hemodynamic stress responses. objectives this study aimed to compare the immediate hemodynamic effects of the insertion of laryngeal mask airway supreme (lma-s) and classic (lma-c) with laryngoscopy and endotracheal intubation (ett). patients and methods this study was a prospective, double-blind, and randomized clinical trial conducted on 150 patients aged 18 to 50 years with asa i (american society of anesthesiologists), in the general operating room of shahid mohammadi hospital, hormozgan university of medical sciences, bandar abbas, iran. in the ett group, endotracheal intubation was performed using the macintosh laryngoscope; while for the lma-c and lma-s groups, lma classic and lma supreme were inserted, respectively. the induction and maintenance of anesthesia were similar in all patients. the hemodynamic parameters such as heart rate (hr), systolic blood pressure (sbp), and diastolic blood pressure (dbp) were measured before (baseline) and after induction of anesthesia at 4 different time points. the statistical analysis was done and p value less than 0.05 was considered significant.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Better Hemodynamic Profile of Laryngeal Mask Airway Insertion Compared to Laryngoscopy and Tracheal Intubation

BACKGROUND Laryngoscopy and tracheal intubation can cause serious cardiovascular responses in patients such as hypertension, tachycardia, and arrhythmias. Alternative airway maintenance techniques may attenuate these hemodynamic stress responses. OBJECTIVES This study aimed to compare the immediate hemodynamic effects of the insertion of laryngeal mask airway supreme (LMA-S) and classic (LMA-...

full text

Comparison of the effect of thiopental sodium-midazolam combination on the hemodynamic response between tracheal intubation and laryngeal mask airway insertion: A clinical trial study

Background and Aim: The purpose of this study was to compare the effect of thiopental sodium-midazolam combination on the stress response and hemodynamic changes between tracheal intubation and laryngeal mask airway insertion during airway management. Materials and Methods: In this clinical trial study, 70 patients ASA 1, 2 candidates for elective surgery were randomly divided into two groups o...

full text

Hemodynamic responses to insertion of the laryngeal mask airway versus Combitube

Introduction: One of the most common problems during laryngoscopy involves sympathetic system stimulation and the subsequent hemodynamic changes. It is a key measure to maintain the hemodynamic stability of patients with cardiovascular diseases during induction of anesthesia. This study attempted to compare the hemodynamic effects of laryngeal mask airway and combitube. Methods: This prospec...

full text

&quot;comparison of hemodynamic changes after insertion of laryngeal mask airway, facemask and endotracheal intubation&quot;

hemodynamic changes are major hazards of general anesthesia and are probably generated by direct laryngoscopy and endotracheal intubation. we designed this prospective randomised study to assess the cardiovascular changes after either laryngeal mask airway (lma), face mask (fm) or endotracheal tube (ett) insertion in the airway management of adult patients anesthetised with nitrous oxide and ha...

full text

Haemodynamic response to tracheal intubation via intubating laryngeal mask airway versus direct laryngoscopic tracheal intubation.

OBJECTIVE To compare the haemodynamic response to tracheal intubation using either direct larygoscopy or Intubating Laryngeal Mask Airway. METHODS This was a prospective randomized controlled trial. One hundred adult ASA-I and ASA-II patients coming to the Anaesthesia Department of Aga Khan University Hospital were randomly divided into two groups. In group-I endotracheal intubation was done ...

full text

Hemodynamic responses and upper airway morbidity following tracheal intubation in patients with hypertension: Conventional laryngoscopy versus an intubating laryngeal mask airway

OBJECTIVES We compared hemodynamic responses and upper airway morbidity following tracheal intubation via conventional laryngoscopy or intubating laryngeal mask airway in hypertensive patients. METHODS Forty-two hypertensive patients received a conventional laryngoscopy or were intubated with a intubating laryngeal mask airway. Anesthesia was induced with propofol, fentanyl, and cis-atracuriu...

full text

My Resources

Save resource for easier access later


Journal title:
iranian red crescent medical journal

جلد ۱۷، شماره ۸، صفحات ۰-۰

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023