the evaluation of survival in patients who need intra aortic balloon pump (iabp) after cardiac surgery
Authors
abstract
introduction: insome cases, assist devices are required to ensure an adequate cardiac output after cardiac surgery. intra-aortic balloon pump (iabp) is the most commonly used cardiac assist device, which provides first-line support for patients with heart failure. the aim of this study was to determine factors affecting the mortality rate of patients receiving iabp. materials & methods: in this retrospective cohort study 235 patients requiring labp support were analyzed over 14 years period (between january 1999 and december 2013) from which 137 patients survived the 30 days follow-up. perioperative and demographic factors such as age, weight, underlying disease, ejection fraction, ventricular aneurysm and cardiopulmonary bypass and cross clamp time were recorded and analyzed. results: the overall operative mortality was reported to be 41.7%. male-to-female ratio was 131:104 and the mean age of the subjects was 57.58 ± 11.07 years. early mortality rate was higher among young subjects and those with prolonged cbp (162.71±35.25, p<0.001) and acc (129.94±54.39, p<0.001). in addition, mortality rate was higher among females (p=0.04). patients’ weight, comorbidity, preoperative ejection fraction, ventricular aneurysm and stenosis of the left main coronary did not affect the mortality rate (p>0.05). conclusion: iabp is a simple, effective method for temporary cardiac support, especially for aged patients. in addition, lower duration of surgery is associated with better surgical outcomes.
similar resources
The Evaluation of Survival in Patients Who Need Intra Aortic Balloon Pump (IABP) after Cardiac Surgery
Introduction: Insome cases, assist devices are required to ensure an adequate cardiac output after cardiac surgery. Intra-aortic balloon pump (IABP) is the most commonly used cardiac assist device, which provides first-line support for patients with heart failure. The aim of this study was to determine factors affecting the mortality rate of patients receiving IABP. Materials & Methods: In thi...
full textThe Evaluation of Survival in Patients Who Need Intra Aortic Balloon Pump (IABP) after Cardiac Surgery
Article type: Original article Introduction: In some cases, assist devices are required to ensure an adequate cardiac output after cardiac surgery. Intra-aortic balloon pump (IABP) is the most commonly used cardiac assist device, which provides first-line support for patients with heart failure. The aim of this study was to determine factors affecting the mortality rate of patients receiving IA...
full textThe role of prophylactic intra-aortic balloon pump counterpulsation (IABP) in emergency non-cardiac surgery.
Patients with recent myocardial infarction (MI), congestive heart failure, severe angina, or uncorrected multivessel coronary artery disease are at increased risk of cardiac complications after urgent major non-cardiac surgery. Although invasive haemodynamic monitoring and preoperative optimization of cardiac status may lead to some reduction in the rate of perioperative cardiac events, the mor...
full textWhen You Need Intra-Aortic Balloon Pump Therapy
© 2000 Arrow International, Inc. Printed in Czech Republic IAB-BK 12/00 5M Part No. IAE-00100 A f t e r t h e t i s s u e s t a k e o x y g e n f r o m t h e b l o o d , i t i s r e t u r n e d t o t h e h e a r t t h r o u g h t h e b o d y ’ s p l u m b i n g , c a l l e d v e i n s . T h e h e a r t , i t s e l f a n o r g a n , h a s a r t e r i e s a n d v e i n s ...
full textنتایج کاربرد بالون پمپ داخل آئورت در بیماران جراحی قلبIntra-Aortic Ballon Pump Outcome in Cardiac Surgical Patients
Background & Aim: Intra-aortic ballon pump(IABP) is a mechanical device that has become an accepted treatment modality for patients with severely compromised hemodynamics. The present retrospective study was undertaken to identify the major survival and nonsurvival determinants of patients who were in need of intra-aortic ballon pump support after cardiac surgery. Patients & Methods: Th...
full textThe need for intra aortic balloon pump support following open heart surgery: risk analysis and outcome
BACKGROUND The early and intermediate outcome of patients requiring intraaortic balloon pump (IABP) was studied in a cohort of 2697 adult cardiac surgical patients. METHODS 136 patients requiring IABP (5.04%) support analysed over a 4 year period. Prospective data collection, obtained. RESULTS The overall operative mortality was 35.3%. The "operation specific" mortality was higher on the Va...
full textMy Resources
Save resource for easier access later
Journal title:
journal of cardio-thoracic medicineجلد ۲، شماره ۴، صفحات ۲۲۷-۲۳۰
Hosted on Doprax cloud platform doprax.com