performance of myocardial perfusion imaging using multi-focus fan beam collimator with resolution recovery reconstruction in a comparison with conventional spect
Authors
abstract
objective: iqspect is an advanced high-speed spect modality for performing myocardial perfusion imaging (mpi), which uses a multi-focus fan beam collimator with resolution recovery reconstruction. the aim of this study was to compare iqspect compared with conventional spect interms of performance based on standard clinical protocols. in addition, we examined the concordance between conventional and iqspect in patients with coronary artery disease (cad). methods: fifty-three patients undergoing rest-gated mpi for the evaluation of known or suspected coronary artery disease were enrolled in this study. in each patient, conventional spect (99mtc-tetrofosmin, 9.6 min; 201tl, 12.9 min) was performed, immediately followed by iqspect, using a short acquisition time (4.3 min for 99mtc-tetrofosmin and 6.2 min for 201tl). a quantitative analysis was performed on an mpi polar map using a 20-segment model of the left ventricle. an automated analysis by gated spect was carried out to determine the left ventricular volume and function, including the end-diastolic volume, end-systolic volume and left ventricular ejection fraction (lvef). the degree of concordance between conventional spect and iq-spect images was evaluated according to linear regression and bland-altman analyses. results: the segmental percent uptake exhibited a significant correlation between iqspect and conventional spect (p<0.05). the mean differences in 99mtc‐tetrofosmin studies were 1.1±6.6% (apex), 2.8±5.7% (anterior wall), 2.9±6.2% (septal wall),4.9±6.7% (lateral wall), and 1.8±5.6% (inferior wall). meanwhile, regarding the 201tl‐spect studies, these values were 1.6±6.9%, 2.0±6.6%, 2.1±5.9%, 3.3±7.2%, and 2.4±5.8%, respectively. although the mean lvef in iq‐spect tended to be higher than that observed in conventional spect (conventional spect=64.8±11.8% and iqspect=68.3±12.1% for 99mtc‐tetrofosmin; conventional spect= 56.0±11.7% and iqspect=61.5±12.2% for 201tl), quantitative parameters were not significantly different between iq‐spect and conventional spect. conclusion: according to the 99mtc‐tetrofosmin and 201tl protocols, iq‐spect images were comparable to and in agreement with conventional spect images. our results suggest that iq‐spect is a useful technology for mpi spect, and can lead to an increase in scan efficiency and patient comfort.
similar resources
Performance of myocardial perfusion imaging using multi-focus fan beam collimator with resolution recovery reconstruction in a comparison with conventional SPECT
Objective: IQSPECT is an advanced high-speed SPECT modality for performing myocardial perfusion imaging (MPI), which uses a multi-focus fan beam collimator with resolution recovery reconstruction. The aim of this study was to compare IQSPECT compared with conventional SPECT interms of performance based on standard clinical protocols. In addition, we examined the concordance between convention...
full textPerformance of Myocardial Perfusion Imaging Using Multi-focus Fan Beam Collimator with Resolution Recovery Reconstruction in a Comparison with Conventional SPECT
OBJECTIVES IQ-SPECT is an advanced high-speed SPECT modality for myocardial perfusion imaging (MPI), which uses a multi-focus fan beam collimator with resolution recovery reconstruction. The aim of this study was to compare IQ-SPECT with conventional SPECT in terms of performance, based on standard clinical protocols. In addition, we examined the concordance between conventional and IQ_SPECT in...
full textDifferential impact of multi-focus fan beam collimation with L-mode and conventional systems on the accuracy of myocardial perfusion imaging: Quantitative evaluation using phantoms
Objective(s): A novel IQ-SPECTTM method has become widely used in clinical studies. The present study compares the quality of myocardial perfusion images (MPI) acquired using the IQ-SPECTTM (IQ-mode),conventional (180° apart: C-mode) and L-mode (90° apart: L-mode) systems. We assessed spatial resolution, image reproducibility and quantifiability using various physical phantoms. Materials and Me...
full textdifferential impact of multi-focus fan beam collimation with l-mode and conventional systems on the accuracy of myocardial perfusion imaging: quantitative evaluation using phantoms
objective(s): a novel iq-specttm method has become widely used in clinical studies. the present study compares the quality of myocardial perfusion images (mpi) acquired using the iq-specttm (iq-mode),conventional (180° apart: c-mode) and l-mode (90° apart: l-mode) systems. we assessed spatial resolution, image reproducibility and quantifiability using various physical phantoms. materials and me...
full textEvaluation of the Reconstruction Parameters of Brain Dopamine Transporter SPECT Images Obtained by a Fan Beam Collimator: A Comparison with Parallel-hole Collimators
Objective(s): The purpose of this study was to examine the optimal reconstruction parameters for brain dopamine transporter SPECT images obtained with a fan beam collimator and compare the results with those obtained by using parallel-hole collimators.Methods: Data acquisition was performed using two SPECT/CT devices, namely a Symbia T6 and an Infinia Hawkeye 4 (device A and B) equipped with fa...
full textMyocardial Perfusion SPECT Imaging in Dextrocardia with Situs Inversus: A Case Report
Dextrocardia is a cardiac positional anomaly in which the heart is located in the right hemithorax with its base-to-apex axis directed to the right and caudad. Situs inversus is an autosomal recessive disorder that causes organs in the chest and abdomen to be positioned in a mirror image from their normal position. Dextrocardia may occur in isolation or as part of situs inversus. Similarly, sit...
full textMy Resources
Save resource for easier access later
Journal title:
asia oceania journal of nuclear medicine and biologyجلد ۲، شماره ۲، صفحات ۱۱۱-۱۱۹
Hosted on Doprax cloud platform doprax.com
copyright © 2015-2023