validation of computed tomography-based attenuation correction of deviation between theoretical and actual values for four computed tomography scanners
Authors
abstract
objective: in this study, we aimed to validate the accuracy of computed tomography-based attenuation correction (ctac) using the bilinear scaling method.methods: the measured attenuation coefficient (μm) was compared to a theoretical attenuation coefficient (μt ) using four different ct scanners and an rmi 467 phantom. the effective energy of the ct beam x-rays was calculated, using the aluminum half-value layer method, and was used in conjunction with an attenuation map to convert the ct numbers to μm values for the photon energy of 140 kev. we measured the ct number of the rmi 467 phantom for each of four scanners, and compared the μm and μt values for the effective energies of the ct beam x-rays, effective atomic numbers, and physical densities.results: the μm values for ct beam x-rays with low effective energies decreased in high construction elements, compared with ct beam x-rays of high effective energies . as the physical density increased, the μm values elevated linearly. compared with other scanners, the μm values obtained from the scanner with ct beam x-rays of the maximal effective energy increased once the effective atomic number exceeded 10.00. the μm value of soft tissue was equivalent to the μt value. however, the ratios of the maximal differences between the μm value and the μt value were 25.4% (lung) and 21.5% (bone) respectively. additionally, the maximal differences in the μm values were 6.0% in the bone tissue for each scanner.conclusion: the bilinear scaling method could accurately convert ct numbers to μ values within the soft tissues.
similar resources
Validation of computed tomography-based attenuation correction of deviation between theoretical and actual values for four computed tomography scanners
Objective: In this study, we aimed to validate the accuracy of computed tomography-based attenuation correction (CTAC) using the bilinear scaling method.Methods: The measured attenuation coefficient (μm) was compared to a theoretical attenuation coefficient (μt ) using four different CT scanners and an RMI 467 phantom. The effective energy of the CT beam X-rays was calculated, using the aluminu...
full textValidation of Computed Tomography-based Attenuation Correction of Deviation between Theoretical and Actual Values in Four Computed Tomography Scanners
OBJECTIVES In this study, we aimed to validate the accuracy of computed tomography-based attenuation correction (CTAC), using the bilinear scaling method. METHODS The measured attenuation coefficient (μm) was compared to the theoretical attenuation coefficient (μt), using four different CT scanners and an RMI 467 phantom. The effective energy of CT beam X-rays was calculated, using the alumin...
full textX-ray-based attenuation correction for positron emission tomography/computed tomography scanners.
A synergy of positron emission tomography (PET)/computed tomography (CT) scanners is the use of the CT data for x-ray-based attenuation correction of the PET emission data. Current methods of measuring transmission use positron sources, gamma-ray sources, or x-ray sources. Each of the types of transmission scans involves different trade-offs of noise versus bias, with positron transmission scan...
full textComputed tomography based attenuation correction in PET/CT: Principles, instrumentation, protocols, artifacts and future trends
The advent of dual-modality PET/CT imaging has revolutionized the practice of clinical oncology, cardiology and neurology by improving lesions localization and the possibility of accurate quantitative analysis. In addition, the use of CT images for CT-based attenuation correction (CTAC) allows to decrease the overall scanning time and to create a noise-free attenuat...
full textTesting of Computed Tomography Scanners
DISCLAIMER: This publication is based on sources and information believed to be reliable, but the AAPM and the editors disclaim any warranty or liability based on or relating to the contents of this publication. The AAPM does not endorse any products, manufacturers or suppliers. Nothing in this publication should be interpreted as implying such endorsement. ©1993 by the American Association of ...
full textAttenuation Correction Strategies for Positron Emission Tomography/Computed Tomography and 4-Dimensional Positron Emission Tomography/Computed Tomography.
This article discusses attenuation correction strategies in positron emission tomography/computed tomography (PET/CT) and 4-dimensional PET/CT imaging. Average CT scan derived from averaging the high temporal resolution CT images is effective in improving the registration of the CT and the PET images and quantification of the PET data. It underscores list-mode data acquisition in 4-dimensional ...
full textMy Resources
Save resource for easier access later
Journal title:
asia oceania journal of nuclear medicine and biologyجلد ۴، شماره ۲، صفحات ۸۱-۸۹
Hosted on Doprax cloud platform doprax.com
copyright © 2015-2023