clinical parameters and crestal bone loss in internal versus external hex implants at one year after loading

Authors

hamidreza arab associate professor of periodontics, dental research center, mashhad university of medical sciences, mashhad, iranسازمان اصلی تایید شده: دانشگاه علوم پزشکی مشهد (mashhad university of medical sciences)

amir moeintaghavi professor of periodontics, dental materials research center, mashhad university of medical sciences, mashhad, iranسازمان اصلی تایید شده: دانشگاه علوم پزشکی مشهد (mashhad university of medical sciences)

naser sargolzaei 1 associate professor of periodontics, dental research center, mashhad university of medical sciences, mashhad, iranسازمان اصلی تایید شده: دانشگاه علوم پزشکی مشهد (mashhad university of medical sciences)

majidreza mokhtari assistant professor of periodontics, dental research center, mashhad university of medical sciences, mashhad, iranسازمان اصلی تایید شده: دانشگاه علوم پزشکی مشهد (mashhad university of medical sciences)

abstract

introduction: the survival of an implant system is affected by the choice of antirotational design, which can include an external or internal hex. implant success also is affected by the maintenance of the crestal bone around implants. the aim of present study was to evaluate the crestal bone loss and clinical parameters related to bone loss in patients loaded with an external or internal hex 3i implant (3i implant innovation, palm beach gardens, fl, usa). the evaluations were performed one year after loading. materials and methods: a total of 39 implants (23 external hex, 16 internal hex) were placed randomly in 23 patients (10 male, 13 female) by a submerged approach. none of patients had compromised conditions or parafunctional habits. at placement and at one year after loading, periapical radiographs were taken via the parallel method from the implant sites. results: crestal bone loss was -0.712±0.831 mm in implants with an internal hex connection and -0.139±0.505 mm in implants with an external hex connection (p≤0.05). no correlation was found between crestal bone loss and parameters such as age, gender, jaw, implant location (anterior, premolar, or molar), implant diameter, or implant length. conclusions: crestal bone loss was greater in patients with internal hex 3i implants than in those with external implants. similar results in other clinical factors were found between the groups.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Clinical Parameters and Crestal Bone Loss in Internal Versus External Hex Implants at One Year after Loading

Introduction: The survival of an implant system is affected by the choice of antirotational design, which can include an external or internal hex. Implant success also is affected by the maintenance of the crestal bone around implants. The aim of present study was to evaluate the crestal bone loss and clinical parameters related to bone loss in patients loaded with an external or internal hex 3...

full text

Radiographic Evaluation of Crestal Bone Loss Around Dental Implants in Maxilla and Mandible: One Year Prospective Clinical Study.

PURPOSE The aim of the study was to analyze the amount of maxillary and mandibular crestal bone loss around Bredent Sky Blue type of implants of different dimensions one year after implantation. MATERIALS AND METHODS 36 implants of diameter 3.5 x 10 mm were inserted in the maxilla and 12 in the mandible. 52 implants of diameter 4.0 x 8 mm were inserted in the maxilla, and 61 in the mandible (...

full text

evaluation of crestal bone loss and stability of immediate functional loading versus immediate non-functional loading of single-mandibular posterior implants: a pilot randomized controlled clinical trial

background: the aim of this study is to evaluate and compare the crestal bone loss and stability of single mandibular posterior dental implants placed in immediate functional loading (ifl) and immediate nonfunctional loading (infl) during 6 months after placement. materials and methods: forty single piece root form titanium implants were placed in 20 patients using ifl and infl techniques. the ...

full text

radiographic vertical bone loss evaluation around dental implants following one year of functional loading

objective: vertical bone loss evaluations in the nobel biocare replace® select tapered tm implant system in the human after one-year loading time. materials and methods: this retrospective cross-sectional study was performed on 31 patients (14 men, 17 women; mean age, 60.39 years) receiving 170 implants (mean, 5.48 for each patient) of groovy and non-groovy designs in the nobel biocare replace®...

full text

My Resources

Save resource for easier access later


Journal title:
journal of dental materials and techniques

جلد ۴، شماره ۳، صفحات ۱۵۱-۱۵۴

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023