Radiologist compliance with California CT dose reporting requirements: a single-center review of pediatric chest CT.

نویسندگان

  • Evan J Zucker
  • David B Larson
  • Beverley Newman
  • Richard A Barth
چکیده

OBJECTIVE Effective July 1, 2012, CT dose reporting became mandatory in California. We sought to assess radiologist compliance with this legislation and to determine areas for improvement. MATERIALS AND METHODS We retrospectively reviewed reports from all chest CT examinations performed at our institution from July 1, 2012, through June 30, 2013, for errors in documentation of volume CT dose index (CTDIvol), dose-length product (DLP), and phantom size. Reports were considered as legally compliant if both CTDIvol and DLP were documented accurately and as institutionally compliant if phantom size was also documented accurately. Additionally, we tracked reports that did not document dose in our standard format (phantom size, CTDIvol for each series, and total DLP). RESULTS Radiologists omitted CTDIvol, DLP, or both in nine of 664 examinations (1.4%) and inaccurately reported one or both of them in 56 of the remaining 655 examinations (8.5%). Radiologists omitted phantom size in 11 of 664 examinations (1.7%) and inaccurately documented it in 20 of the remaining 653 examinations (3.1%). Of 664 examinations, 599 (90.2%) met legal reporting requirements, and 583 (87.8%) met institutional requirements. In reporting dose, radiologists variably used less decimal precision than available, summed CTDIvol, included only series-level DLP, and specified dose information from the scout topogram or a nonchest series for combination examinations. CONCLUSION Our institutional processes, which primarily rely on correct human performance, do not ensure accurate dose reporting and are prone to variation in dose reporting format. In view of this finding, we are exploring higher-reliability processes, including better-defined standards and automated dose reporting systems, to improve compliance.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical Value of Low Dose CT- Scan in Pediatric Chest Diseases: Adequacy Assessment

Background Radiation dose about 400 times that of standard thoracic computed tomography (CT) in comparison with chest X- ray resulting in different approaches to decrease radiation dose have been established in the last few years to prevent possible side effects especially in children, such as low dose protocols. The aim of this study was assessment of clinical v...

متن کامل

Assessment of compliance levels of effective doses in pediatric CT

Introduction: Computed tomography (CT) is a medical imaging modality that produces 3-D cross-sectional images of tissues using several X-ray projections at different angles. Since its introduction in the 1970s, CT usage has been on the increase for both adults and pediatrics. A major challenge of this modality is the high doses of radiation exposure to patients, especially in p...

متن کامل

Reducing radiation doses in female breast and lung during CT examinations of thorax: A new technique in two scanners

Background: Chest CT is a commonly used examination for the diagnosis of lung diseases, but a breast within the scanned field is nearly never the organ of interest.Objective: The purpose of this study is to compare the female breast and lung doses using split and standard protocols in chest CT scanning.Materials and Methods: The sliced chest and breast female phantoms were used. CT exams were p...

متن کامل

Assessment of Patient Dose from CT Examinations in Khorasan, Iran

Introduction Computed Tomography scans are a very important tool for diagnosis and assessment of response to treatment in the practice of medicine. Ionizing radiation in medical imaging is undoubtedly one of the most powerful diagnostic tools in medicine. Yet, as with all medical interventions, there are potential risks in addition to the clear potential benefits. Materials and Methods Two refe...

متن کامل

Conventional and spiral CT dose indices in Yazd general hospitals, Iran

  ABSTRACT   Background: While the benefits of Computed Tomography (CT) are well known in accurate diagnosis, those benefits are not risk free. CT is a device with higher patient dose in comparison with other conventional radiological procedures. Is the reduction of exposures by requiring optimization of CT procedures [a principle concern in radiological protection]? In this study, the radiatio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJR. American journal of roentgenology

دوره 204 4  شماره 

صفحات  -

تاریخ انتشار 2015