Appropriate use of nasal continuous positive airway pressure decreases elevated C-reactive protein in patients with obstructive sleep apnea.

نویسندگان

  • Katsunori Ishida
  • Masahiko Kato
  • Yosuke Kato
  • Kiyotaka Yanagihara
  • Yoshiharu Kinugasa
  • Kazuhiko Kotani
  • Osamu Igawa
  • Ichiro Hisatome
  • Chiaki Shigemasa
  • Virend K Somers
چکیده

BACKGROUND C-reactive protein (CRP) is an important risk factor for cardiovascular disease. Furthermore, it has been reported that levels of CRP are increased in patients with obstructive sleep apnea (OSA). The aim of this study was to examine the effects of long-term therapy with nasal continuous positive airway pressure (nCPAP) on CRP levels and to investigate whether compliance with nCPAP therapy more effectively attenuated markers of systemic inflammation in patients with OSA. METHODS AND RESULTS Fifty-five patients (mean [+/- SEM] age, 55 +/- 2 years; 44 male patients, 11 female patients) with newly diagnosed moderate-to-severe OSA (apnea-hypopnea index > 20 events/h) were studied before and after 6 months of nCPAP treatment. There was a significant reduction in CRP levels after nCPAP therapy (before nCPAP therapy, 0.23 +/- 0.03 mg/dL; after nCPAP therapy, 0.17 +/- 0.02 mg/dL; p < 0.01). Additionally, we divided these patients into two groups based on adherence to nCPAP therapy. A group of patients using nCPAP > 4 h/d and > 5 d/wk were designated as the good compliance group. The decrease in CRP concentration was significant (before nCPAP therapy, 0.23 +/- 0.04 mg/dL; after nCPAP therapy, 0.16 +/- 0.03 mg/dL; p < 0.05) in the good compliance group but not in the poor compliance group (before nCPAP therapy, 0.24 +/- 0.05 mg/dL; after nCPAP therapy, 0.20 +/- 0.05 mg/dL; p = 0.21). Furthermore, we divided those patients into a high CRP group (>/= 0.2 mg/dL) and a normal CRP group (< 0.2 mg/dL) before nCPAP therapy. The significant decrease in CRP levels in the good compliance group was evident only in those patients with an initially elevated CRP level (before nCPAP therapy, 0.48 +/- 0.08 mg/dL; after nCPAP therapy, 0.29 +/- 0.06 mg/dL; p < 0.05). CONCLUSION Appropriate use of nCPAP in patients with OSA may be required to decrease elevated CRP levels, with possible implications for cardiovascular morbidity and mortality.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Factors Affecting Patients’ Adherence to Continuous Positive Airway Pressure Therapy for Obstructive Sleep Apnea Disorder: A Multi-Method Approach

Background: Continuous positive airway pressure (CPAP) is the gold standard therapy for treating obstructive sleep apnea (OSA) disorder. However, patients’ adherence to its regular use is poor. The present study aimed to determine the adherence rate to CPAP therapy by identifying factors affecting its regular use and its associated problems and discomforts among a sample population in Mashhad (...

متن کامل

The use of nasal dilator strips as a placebo for trials evaluating continuous positive airway pressure

OBJECTIVES The aim of the current study was to compare the objective and subjective effects of continuous positive airway pressure to the use of nasal dilator strips in patients with acromegaly and moderate to severe obstructive sleep apnea. METHODS We studied 12 patients with acromegaly and moderate to severe obstructive sleep apnea (male/ females = 8/4, age = 52 ± 8 ys, body mass index = 33...

متن کامل

Obstructive Sleep Apnea in Ischemic Stroke patients

OBJECTIVE To investigate the prevalence of obstructive sleep apnea in patients with ischemic stroke and to evaluate the effectiveness of nasal continuous positive airway pressure treatment. METHODS Overnight polysomnography was performed by a computerized system in 19 subjects with ischemic stroke. Patients with an apnea-hypopnea index > or = 5 were considered to have obstructive sleep apnea....

متن کامل

Elevated levels of C-reactive protein and interleukin-6 in patients with obstructive sleep apnea syndrome are decreased by nasal continuous positive airway pressure.

BACKGROUND C-reactive protein (CRP) and interleukin (IL)-6 are important risk factors for atherosclerosis and coronary heart disease. In the present study, we examined serum levels of CRP and IL-6, IL-6 production by monocytes, and the effect of nasal continuous positive airway pressure (nCPAP) in patients with obstructive sleep apnea syndrome (OSAS). METHODS AND RESULTS After polysomnography...

متن کامل

The Impact of Obstructive Sleep Apnoea and Nasal Continuous Positive Airway Pressure on Circulating Ischaemia-Modified Albumin Concentrations

The aim of the present study was to evaluate the impact of obstructive sleep apnoea syndrome (OSAS) and the effects of nasal continuous positive airway pressure (CPAP) on circulating ischaemia-modified albumin (IMA) concentrations. The study included 97 newly diagnosed OSAS patients and 30 nonapnoeic controls. Blood samples were obtained in the morning after polysomnography. After 3 months of C...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Chest

دوره 136 1  شماره 

صفحات  -

تاریخ انتشار 2002