High variability and low irradiance of phototherapy devices in Dutch NICUs.

نویسندگان

  • Deirdre E van Imhoff
  • Christian V Hulzebos
  • Maaike van der Heide
  • Vera W van den Belt
  • Hendrik J Vreman
  • Peter H Dijk
چکیده

OBJECTIVE To evaluate phototherapy practices by measuring the irradiance levels of phototherapy (PT) devices. DESIGN Prospective study. SETTING Tertiary neonatal intensive care units. PATIENTS None. INTERVENTIONS Irradiance levels of PT devices used in the 10 Dutch Neonatal Intensive Care Units (NICUs) were measured according to the local PT practice patterns. The irradiance levels of all overhead and fibre-optic PT devices were measured with a radiometer using an infant silhouette model. RESULTS Eight different PT devices were used in the 10 NICUs; five were overhead devices and three fibre-optic pads. The median (range) irradiance level for overhead PT devices was 9.7 (4.3-32.6) µW/cm(2)/nm and for fibre-optic pads 6.8 (0.8-15.6) µW/cm(2)/nm. Approximately 50% of PT devices failed to meet the minimal recommended irradiance level of 10 µW/cm(2)/nm. Maximal irradiance levels for overhead PT spot lights were inversely related to the distance between device and infant model (R2=0.33). The distances ranged from 37 cm to 65 cm. CONCLUSIONS PT devices in the Dutch NICUs show considerable variability with often too low irradiance levels. These results indicate that suboptimal PT is frequently applied and may even be ineffective towards reducing total serum bilirubin levels. These results underline the need for greater awareness among all healthcare workers towards the requirements for effective PT including measurements of irradiance and distance.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of phototherapy devices used for neonatal hyperbilirubinemia.

OBJECTIVE To compare phototherapy devices based on their physical and photo-biological characteristics viz spectral properties, maximum and mean irradiance, treatable percentage of body surface area, decay of irradiance over time and in vitro photoisomerisation of bilirubin. DESIGN In vitro experimental study. SETTING Ocular pharmacy laboratory at a tertiary care hospital. METHODLOGY: All t...

متن کامل

Irradiance of phototherapy equipment in maternity wards in Maceió.

The effectiveness of neonatal hyperbilirubinaemia treatment depends directly on the amount of energy emitted by light (irradiance). This cross-sectional study aimed to determine the irradiance of phototherapy equipment in maternity wards in Maceió, AL, Brazil. All equipment in use in the neonatal units in Maceió was included in the study, totaling 36 devices, except those in maintenance. The me...

متن کامل

Mist and water condensation inside incubators reduce the efficacy of phototherapy.

OBJECTIVE To measure the irradiance in humidified incubator under three different overhead phototherapy devices. DESIGN/METHODS The effective irradiance of three phototherapy devices was assessed by taking a series of irradiance measurements in the illuminated field. Measurements were made with a fixed bandwidth broadband radiometer (380-530 nm). The distance between the light source and the ...

متن کامل

Phototherapy device effectiveness in Nigeria: irradiance assessment and potential for improvement.

This study investigated the effectiveness of simple-to-implement adjustments of phototherapy devices on irradiance levels in a cross-section of Nigerian hospitals. A total of 76 phototherapy devices were evaluated in 16 hospitals while adjustments were implemented for a subset of 25 devices for which consent was obtained. The mean irradiance level was 7.6 ± 5.9 µW/cm(2)/nm for all devices prior...

متن کامل

[Standardizing the calibration of phototherapy devices - a proposal]

OBJECTIVE: To propose a method to evaluate and maintain the efficiency of equipment commonly used in Brazil in order to obtain uniform results in phototherapy treatments in different services. MATERIAL AND METHODS: The radiometer/photometer used to measure spectral irradiance is locally manufactured and fulfills basic requirements. Measure standardization seeks to be applicable and reproducible...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Archives of disease in childhood. Fetal and neonatal edition

دوره 98 2  شماره 

صفحات  -

تاریخ انتشار 2013