The Percentage of Error of Different Weight Estimation Methods toward Actual Weight in Children Admitted to 17 Shahrivar Hospital

نویسندگان

  • Hamidreza Badeli
  • Houman Hashemian
  • Nima Nazari
  • Afagh Hassanzadeh Rad
چکیده

BACKGROUND In pediatric resuscitation, it is necessary to distinguish the weight in order to provide proper doses of drugs, equipment selection, and ventilator settings, therefore, access to a simple, unbiased, and accurate formula can decrease mistakes. The aim of this study is to determine the percentage of error (PE) of different weight estimation methods toward actual weight in children admitted to 17 Shahrivar Hospital. METHODS This is a descriptive cross-sectional study conducted on 1-10 years children admitted in the pediatric clinic of 17 Shahrivar Hospital in Rasht. Data were collected by a checklist, including age, sex, height and mid-arm circumference (MAC). Investigators compared estimated weight by ten different methods with the actual weight. Finally, clinicians measured the PE and data were analyzed in SPSS software version.18. RESULTS About 50.9% of participants were male. The mean age was 4.59 ± 3.35 years and the mean weight was 17.4 ± 5.69 (6.5-45) kg. Results showed no significant difference between the estimated weight and the actual one based on visual expert estimation and advanced pediatric life support (APLS) method. Visual estimation (0.017%) and MAC (25.48%) noted the lowest and highest PE, respectively. CONCLUSIONS Results indicated a significant difference between the estimated weight and the actual one based on visual expert's estimation and APLS method. As, these methods were easy, rapid and accurate for body weight estimation in emergencies and may be more accurate than parent's estimation, it seems that it could be helpful for prescribing medication dosage and equipment sizes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Estimation of Fetal Weight by Clinical Methods and Ultrasonography and Comparing With Actual Birth Weight

Introduction: Assessment of fetal weight is a vital factor in antenatal care, not only in the management of labor and delivery but also in identifying fetal weight disorders. Objective: This study compares the accuracy of clinical methods and ultrasonography in Estimating Fetal Weight (EFW) with Actual Birth Weight (ABW) in term pregnant women. Materials and Methods: This diagnostic test eval...

متن کامل

Evaluation of the Mercy weight estimation method in Ouelessebougou, Mali

BACKGROUND This study evaluated the performance of a new weight estimation strategy (Mercy Method) with four existing weight-estimation methods (APLS, ARC, Broselow, and Nelson) in children from Ouelessebougou, Mali. METHODS Otherwise healthy children, 2 mos to 16 yrs, were enrolled and weight, height, humeral length (HL) and mid-upper arm circumference (MUAC) obtained by trained raters. Weig...

متن کامل

Using the Mercy Method for Weight Estimation in Indian Children

This study was designed to compare the performance of a new weight estimation strategy (Mercy Method) with 12 existing weight estimation methods (APLS, Best Guess, Broselow, Leffler, Luscombe-Owens, Nelson, Shann, Theron, Traub-Johnson, Traub-Kichen) in children from India. Otherwise healthy children, 2 months to 16 years, were enrolled and weight, height, humeral length (HL), and mid-upper arm...

متن کامل

Incidence and risk factors of pneumothorax in premature low birth weight infants under mechanical ventilation

Objective: pulmonary air-leakage especially pneumothorax (ptx), is a severe complication in neonates. The aim of this study was to assess the predisposing factors and frequency of ptx among the low birth weight (LBW) premature infants, under mechanical ventilation. Methods: This cross sectional study was performed in 121 LBW intubated premature infants at neonatal intensive care unit of a child...

متن کامل

Cephalometric Measurements in Infants with Congenital Heart Disease Compared to Healthy Infants

Introduction: The lack of adequate blood perfusion through different organs of the body, including the brain and skull, can be caused by any type of circulation abnormality. The purpose of this study is to compare cephalometric indices between infants under the age of 12 months who have congenital heart disease (CHD) and normal infants. Materials and Methods: This case-control study was ca...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2015