The incidence of physiological radiolucency following Oxford unicompartmental knee replacement and its relationship to outcome.

نویسندگان

  • A Gulati
  • R Chau
  • H G Pandit
  • H Gray
  • A J Price
  • C A F Dodd
  • D W Murray
چکیده

Narrow, well-defined radiolucent lines commonly observed at the bone-implant interface of unicompartmental knee replacement tibial components have been referred to as physiological radiolucencies. These should be distinguished from pathological radiolucencies, which are poorly defined, wide and progressive, and associated with loosening and infection. We studied the incidence and clinical significance of tibial radiolucent lines in 161 Oxford unicondylar knee replacements five years after surgery. All the radiographs were aligned with fluoroscopic control to obtain views parallel to the tibial tray to reveal the tibial bone-implant interface. We found that 49 knees (30%) had complete, 52 (32%) had partial and 60 (37%) had no radiolucent lines. There was no relationship between the incidence of radiolucent lines and patient factors such as gender, body mass index and activity, or operative factors including the status of the anterior cruciate ligament and residual varus deformity. Nor was any statistical relationship established between the presence of radiolucent lines and clinical outcome, particularly pain, assessed by the Oxford Knee score and the American Knee Society score. We conclude that radiolucent lines are common after Oxford unicompartmental knee replacement but that their aetiology remains unclear. Radiolucent lines were not a source of adverse symptoms or pain. Therefore, when attempting to identify a source of postoperative pain after Oxford unicompartmental knee replacement the presence of a physiological radiolucency should be ignored.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Early Results of Oxford Mobile Bearing Medial Unicompartmental Knee Replacement (UKR) with the Microplasty Instrumentation: An Indian Experience

Background: Oxford medial unicompartmental knee replacement (UKR) is indicated in patients with anteromedialosteoarthritis (AMOA) of the knee. Microplasty (MP) instrumentation was introduced in 2012 as an improvement overphase 3 instrumentation. Advantages of this instrumentation include conservative tibial cut, decreased tibial re-cut rateand improved component alignment. We report the results...

متن کامل

Pre-operative clinical and radiological assessment of the patellofemoral joint in unicompartmental knee replacement and its influence on outcome.

Anterior knee pain and/or radiological evidence of degeneration of the patellofemoral joint are considered to be contraindications to unicompartmental knee replacement. The aim of this study was to determine whether this is the case. Between January 2000 and September 2003, in 100 knees (91 patients) in which Oxford unicompartmental knee replacements were undertaken for anteromedial osteoarthri...

متن کامل

Oxford unicompartmental knee arthroplasty: medial pain and functional outcome in the medium term

BACKGROUND In our experience results of the Oxford unicompartmental knee replacement have not been as good as had been expected. A common post operative complaint is of persistent medial knee discomfort, it is not clear why this phenomenon occurs and we have attempted to address this in our study. METHODS 48 patients were retrospectively identified at a mean of 4.5 years (range = 3 to 6 years...

متن کامل

Revision surgery for failed unicompartmental knee replacement: technical aspects and clinical outcome.

The aims of this study were to determine the complexity of surgery required to revise failed unicompartmental knee replacements and to evaluate the outcome following revision. Between 2000 and 2009, 494 cemented Oxford phase 3 medial unicompartmental knee replacements were implanted, with 24 (4.9%) requiring revision (mean age: 63.5 years; 58% male). Mean time to revision was 3.0 years. All cas...

متن کامل

Cementless Oxford unicompartmental knee replacement shows reduced radiolucency at one year.

We randomised 62 knees to receive either cemented or cementless versions of the Oxford unicompartmental knee replacement. The implants used in both arms of the study were similar, except that the cementless components were coated with porous titanium and hydroxyapatite. The tibial interfaces were studied with fluoroscopically-aligned radiographs. At one year there was no difference in clinical ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of bone and joint surgery. British volume

دوره 91 7  شماره 

صفحات  -

تاریخ انتشار 2009