Analysis of a Singular Perturbed Synchronous Generator with a Bond Graph Approach
ثبت نشده
چکیده
An analysis of a synchronous generator in a bond graph approach is proposed. This bond graph allows to determine the simplified models of the system by using singular perturbations. Firstly, the nonlinear bond graph of the generator is linearized. Then, the slow and fast state equations by applying singular perturbations are obtained. Also, a bond graph to get the quasi-steady state of the slow dynamic is proposed. In order to verify the effectiveness of the singularly perturbed models, simulation results of the complete system and reduced models are shown. Keywords—Bond graph modelling, synchronous generator, singular perturbations
منابع مشابه
Analysis of Magnetic Flux Linkage Distribution in Salient-Pole Synchronous Generator with Different Kinds of Inter-Turn Winding Faults
A reliable and accurate diagnosis of inter-turn short circuit faults is a challenging problem in the area of fault diagnosis of electrical machines. The purpose of this challenge is to be more efficient in fault detection and to provide a reliable method with low-cost sensors and simple numerical algorithms which not only detect the occurrence of the fault, but also locate its position in the w...
متن کاملApplication of Radial Basis Neural Networks in Fault Diagnosis of Synchronous Generator
This paper presents the application of radial basis neural networks to the development of a novel method for the condition monitoring and fault diagnosis of synchronous generators. In the proposed scheme, flux linkage analysis is used to reach a decision. Probabilistic neural network (PNN) and discrete wavelet transform (DWT) are used in design of fault diagnosis system. PNN as main part of thi...
متن کاملAnalysis and Design of a Permanent-Magnet Outer-Rotor Synchronous Generator for a Direct-Drive Vertical-Axis Wind Turbine
In Permanent-Magnet Synchronous Generators (PMSGs) the reduction of cogging torque is one of the most important problems in their performance and evaluation. In this paper, at first, a direct-drive vertical-axis wind turbine is chosen. According to its nominal value operational point, necessary parameters for the generator is extracted. Due to an analytical method, four generators with differen...
متن کاملModeling of a Rectifier Connected PMSG Applied in Wind Energy Conversion System Using State Machine Approach
Accurate modeling of the wind energy conversion system is necessary to design and implementation of the control loop for the generator and the frequency converter, in order to extract maximum power from the wind and to investigate the effects of interconnection between wind farms and power system. In this paper the combination of a permanent magnet synchronous generator loaded with a diode rect...
متن کاملControl and stability improvement of combined wind-battery system with permanent magnet synchronous generator supplying active load
This paper deals with the control and stability enhancement of a wind power generation system feeding active load with constant power characteristic. The under study system is a combined wind-battery generation system with permanent magnet synchronous generator (PMSG) supplying active load by using interfaced power electronics converters. The employed active load is indeed an active rectifier b...
متن کامل