Reliability of RT3 accelerometer for measuring mobility in people with multiple sclerosis: pilot study.
نویسندگان
چکیده
This pilot study investigated the test-retest reliability of an RT3 accelerometer (RT3) for measuring motion in people with multiple sclerosis (MS). Ten people with MS (mean age 49 yr; Extended Disability Status Scale mean +/- standard deviation = 3.4 +/- 1.3) and ten nondisabled people (mean age 40 yr) wore the RT3 while they performed three discrete mobility tasks on two occasions separated by 1 week. The intraclass correlation coefficients (ICCs) calculated from the RT3 motion data for the group with MS were 0.64 for the 5-minute walk test (p = 0.01), 0.50 for the timed up and go test (p = 0.05), and 0.76 for the stair-climbing task (p = 0.002). For the control group, these values were 0.65 (p = 0.01), -0.04 (p = 0.54), and 0.39 (p = 0.11), respectively. We found that the RT3 can potentially provide stable data when measuring walking, but a more robust, yet participant-friendly, method of attaching the RT3 is required. Both participant groups demonstrated inconsistencies in motor-task performance, highlighting a potential source of measurement error that would need to be addressed when future studies are designed. Based on the results of the 5-minute walk test in this study, a sample of 53 participants would be required to obtain an ICC value with a 95% confidence interval of width 0.2 using two repeat measurements.
منابع مشابه
Evaluation of Reliability and Validity of the Persian Version of Fatigue Severity Scale (FSS) among Persons with Multiple Sclerosis
Objective: The aim of this study was to evaluate different aspects of validity and reliability of the Persian-version of Fatigue Severity Scale (FSS-P) among people with Multiple Sclerosis. Materials & Methods: A sample of 50 people with Multiple Sclerosis and 30 healthy adults were included in this study. The participants were recruited from Sina clinic in Tehran between 2001 to 2007. The F...
متن کاملInterinstrument reliability of the RT3 accelerometer.
The objective of this study was to assess the interinstrument reliability of six RT3 accelerometers for measuring physical activities. Each of the six healthy participants, mean age 36.1 years (SD 9.4), carried six RT3 accelerometers (same type and same producer) simultaneously placed ventrally at the waist belt. The participants performed three standardized activities: walking on a treadmill a...
متن کاملبررسی پایایی آزمون ارزیابی عملکردی مهارت های خود مراقبتی (PASS) در بررسی مراقبت از خود بیماران Multiple Sclerosis بزرگسال مراجعه کننده به بخشهای توانبخشی شهر تهران
Objective: The purpose of the present study was to assess the reliability of PASS in evaluating the self-care skills of patient suffering from multiple sclerosis. Materials & Methods: The present study is an analytic-descriptive study in which 30 adults suffering from multiple sclerosis (MS) underwent reliability evaluation of PASS in Tehran city with an interval of two weeks. Participants w...
متن کاملConstruct validity of RT3 accelerometer: A comparison of level-ground
This study examined differences in accelerometer output when subjects walked on level ground and on a treadmill. We asked 25 nondisabled participants to wear an RT3 triaxial accelerometer (StayHealthy, Inc; Monrovia, California) and walk at their “normal” and “brisk” walking speeds for 10 minutes. These activities were repeated on a treadmill using the individual speeds from level-ground walkin...
متن کاملInvestigating Environmental Barriers Affecting Participation in Patient With Multiple Sclerosis
Objective: The participation, Based on International Classification of Functioning, Disability And Health (ICF), is part of healthy function that leads to the development of skills and a sense of competence and confidence in them. People with multiple sclerosis experience problems in various areas of participation. Environmental factors can create serious restrictions in the level of participa...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of rehabilitation research and development
دوره 44 4 شماره
صفحات -
تاریخ انتشار 2007