Germicidal ultraviolet irradiation in air conditioning systems: effect on office worker health and wellbeing: a pilot study.
نویسندگان
چکیده
OBJECTIVES The indoor environment of modern office buildings represents a new ecosystem that has been created totally by humans. Bacteria and fungi may contaminate this indoor environment, including the ventilation systems themselves, which in turn may result in adverse health effects. The objectives of this study were to test whether installation and operation of germicidal ultraviolet (GUV) lights in central ventilation systems would be feasible, without adverse effects, undetected by building occupants, and effective in eliminating microbial contamination. METHODS GUV lights were installed in the ventilation systems serving three floors of an office building, and were turned on and off during a total of four alternating 3 week blocks. Workers reported their environmental satisfaction, symptoms, as well as sickness absence, without knowledge of whether GUV lights were on or off. The indoor environment was measured in detail including airborne and surface bacteria and fungi. RESULTS Airborne bacteria and fungi were not significantly different whether GUV lights were on or off, but were virtually eliminated from the surfaces of the ventilation system after 3 weeks of operation of GUV light. Of the other environmental variables measured, only total airborne particulates were significantly different under the two experimental conditions--higher with GUV lights on than off. Of 113 eligible workers, 104 (87%) participated; their environmental satisfaction ratings were not different whether GUV lights were on or off. Headache, difficulty concentrating, and eye irritation occurred less often with GUV lights on whereas skin rash or irritation was more common. Overall, the average number of work related symptoms reported was 1.1 with GUV lights off compared with 0.9 with GUV lights on. CONCLUSION Installation and operation of GUV lights in central heating, ventilation and air conditioning systems of office buildings is feasible, cannot be detected by workers, and does not seem to result in any adverse effects.
منابع مشابه
Effect of ultraviolet germicidal lights installed in office ventilation systems on workers' health and wellbeing: double-blind multiple crossover trial.
BACKGROUND Workers in modern office buildings frequently have unexplained work-related symptoms or combinations of symptoms. We assessed whether ultraviolet germicidal irradiation (UVGI) of drip pans and cooling coils within ventilation systems of office buildings would reduce microbial contamination, and thus occupants' work-related symptoms. METHODS We undertook a double blind, multiple cro...
متن کاملThe application of ultraviolet germicidal irradiation to control transmission of airborne disease: bioterrorism countermeasure.
Bioterrorism is an area of increasing public health concern. The intent of this article is to review the air cleansing technologies available to protect building occupants from the intentional release of bioterror agents into congregate spaces (such as offices, schools, auditoriums, and transportation centers), as well as through outside air intakes and by way of recirculation air ducts. Curren...
متن کاملAnnual Simulation of In-duct Ultraviolet Germicidal Irradiation System Performance
In-duct ultraviolet germicidal irradiation (UVGI) systems treat moving air streams in heating, ventilation, and air-conditioning (HVAC) systems to inactivate airborne microorganisms. UVGI system performance depends on air temperature, velocity, cumulative operating time, variations in exposure time and other factors. Annual simulations of UVGI efficiency and space concentration that accounted f...
متن کاملApplications of ultraviolet germicidal irradiation disinfection in health care facilities: effective adjunct, but not stand-alone technology.
This review evaluates the applicability and relative contribution of ultraviolet germicidal irradiation (UVGI) to disinfection of air in health care facilities. A section addressing the use of UVGI for environmental surfaces is also included. The germicidal susceptibility of biologic agents is addressed, but with emphasis on application in health care facilities. The balance of scientific evide...
متن کاملLife-cycle Cost Simulation of In-duct Ultraviolet Germicidal Irradiation Systems
Ultraviolet Germicidal Irradiation (UVGI) systems use 254 nm UVC radiation to inactivate microorganisms in the air and on surfaces. In-duct UVGI systems are installed in air-handling units or air distribution systems to inactivate microorganisms “on the fly” and on surfaces. The literature contains few investigations of the economic performance of UVGI. This study presents a simulation-based li...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Occupational and environmental medicine
دوره 56 6 شماره
صفحات -
تاریخ انتشار 1999