Registration of MR and SPECT without using external fiducial markers.

نویسندگان

  • J C de Munck
  • F C Verster
  • E A Dubois
  • J B Habraken
  • B Boltjes
  • J J Claus
  • M van Herk
چکیده

The aim of our work is to present, test and validate an automated registration method used for matching brain SPECT scans with corresponding MR scans. The method was applied on a data set consisting of ten brain IDEX SPECT scans and ten T1- and T2-weighted MR scans of the same subjects. Of two subjects a CT scan was also made. (Semi-) automated algorithms were used to extract the brain from the MR, CT and SPECT images. Next, a surface registration technique called chamfer matching was used to match the segmented brains. A perturbation study was performed to determine the sensitivity of the matching results to the choice of the starting values. Furthermore, the SPECT segmentation threshold was varied to study its effect on the resulting parameters and a comparison between the use of MR T1- and T2-weighted images was made. Finally, the two sets of CT scans were used to estimate the accuracy by matching MR to CT and comparing the MR-SPECT match to the SPECT-CT match. The perturbation study showed that for initial perturbations up to 6 cm the algorithm fails in less than 4% of the cases. A variation of the SPECT segmentation threshold over a realistic range (25%) caused an average variation in the optimal match of 0.28 cm vector length. When T2 is used instead of T1 the stability of the algorithm is comparable but the results are less realistic due the large deformations. Finally, a comparison of the direct SPECT-MR match and the indirect match with CT as intermediate yields a discrepancy of 0.4 cm vector length. We conclude that the accuracy of our automatic matching algorithm for SPECT and MR, in which no external markers were used, is comparable to the accuracies reported in the literature for non-automatic methods or methods based on external markers. The proposed method is efficient and insensitive to small variations in SPECT segmentation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Image registration accuracy of an in-house developed patient transport system for PET/CT+MR and SPECT+CT imaging.

OBJECTIVE The aim of this study was to investigate the registration accuracy of a newly developed patient shuttle system that can integrate different scanners by patient transfer without repositioning for 'hardware'-based image fusion. We aimed to assess the registration accuracy of image fusion in two different settings: a trimodality PET/CT+MR system and a SPECT+CT system. MATERIALS AND MET...

متن کامل

Assessment of fiducial markers to enable the co-registration of photographs and MRI data.

PURPOSE To investigate the visualisation of novel external fiducial skin markers in photography and MRI. To co-register photographs and MR images, and additionally assess the spatial accuracy of these co-registrations with the view of future application in the investigation of forensically relevant soft tissue lesions. METHODS AND MATERIALS Strand-shaped fiducial markers were secured external...

متن کامل

Finite-element method for intermodality nonrigid breast registration using external skin markers

We are developing a method using nonrigid co-registration of PET and MR breast images as a way to improve diagnostic specificity in difficult-to-interpret mammograms, and ultimately to avoid biopsy. A deformable breast model based on a finite-element method (FEM) has been employed. The FEM “loads” are taken as the observed intermodality displacements of several fiducial skin markers placed on t...

متن کامل

Registration of three-dimensional MR and CT studies of the cervical spine.

A three-dimensional image registration technique for CT and MR studies of the cervical spine was evaluated for feasibility and efficacy. Registration by means of external fiducial markers was slightly more accurate than registration by anatomic landmarks. The interrelationships between bony (eg, neural foramina) and soft tissue structures (eg, nerve roots) in the cervical spine were more conspi...

متن کامل

Automatic fiducial localization in brain images

Dept of Computer Science and Engineering, Oakland University, USA Institute for Scientific Computing , Wayne State University, USA Abstract. Point-based registration is one of the most popular registration methods in practice. During registration, we use external fiducial markers that are rigidly attached through the skin to the skull. Determining the coordinates of the fiducials without human ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 43 5  شماره 

صفحات  -

تاریخ انتشار 1998