Two-body wear of dental restorative materials.

نویسندگان

  • Sebastian Hahnel
  • Sabine Schultz
  • Christina Trempler
  • Bastian Ach
  • Gerhard Handel
  • Martin Rosentritt
چکیده

AIM The aim of this in vitro study was to determine the two-body wear resistance of modern direct dental restorative materials. METHODS Eight standardized specimens were prepared from 14 dental restorative materials (nano-, micro-, hybrid-, macrofilled composites; compomer, silorane, ormocer); a veneering composite (Sinfony) and enamel were used for reference. Vickers hardness (HV) and inorganic filler weight were determined. Specimens were subjected to mastication simulation using a mastication simulator (50 N, 1.2×10(5) cycles, 1.2 Hz) in a pin-on-block design and simultaneous thermal cycling (600 cycles, 5/55 °C, 2 min/cycle). Steatite balls were used as antagonists. Vertical substance and volume loss were determined using cast replicas and a 3D laser scanning device. Means and standard deviations were calculated, and statistical analysis was performed using one-way ANOVA and the Games-Howell test for post hoc analysis (α=.05). RESULTS HV ranged between 19 and 76; inorganic filler weight ranged between 44% and 88%. Significantly lowest vertical substance and volume loss were detected for the microfilled composite Heliomolar; enamel yielded similar vertical substance and volume loss. Intermediate wear was found for the other microfilled and hybrid composites as well as the silorane and the ormocers. Significantly highest wear was found for the macrofilled composite Quixfil and the compomer Compoglass F. DISCUSSION Within the limitations of an in vitro study, the findings indicate similar wear behaviour for silorane- and ormocer-based dental restorative materials. However, correlations between HV, filler content, and wear resistance were poor.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

350-356 Yip (new)

350 The excessive differential wear of teeth and restorative materials has significant deleterious effects on the biologic, functional, and esthetic condition of the masticatory system. However, controlled investigations of numerous factors that might influence tooth and restoration wear have been mainly laboratory studies, the findings of which might not correlate with either the physical prop...

متن کامل

Wear of dental amalgam.

The wear of cental amalgam was studied by single- and double-pass sliding and by a silicon carbide abrasion test. A dispersed amalgam showed significantly better resistance to two-body abrasion than the spherical amalgams tested. The wear amalgam was determined by resistance to penetration and by a ductile mode of surface failure over the load range studied. Differences in the wear of amalgam a...

متن کامل

Mechanics of Contact and Lubrication, MTM G230 Department of Mechanical & Industrial Engineering Northeastern University Spring 2006 Wear of Dental Restorative Materials

Gradual wear of opposing teeth is a normal phenomenon in human dentition. To ensure a better quality of life through better dental health, there is a need for quality dental restorative materials to repair or replace natural teeth. Several aspects are looked at when designing a proper dental implant. Aesthetics, durability, and integration with the supporting teeth and soft tissues are some key...

متن کامل

بررسی اثر نوع فیلر بر سایش سه جزئی کامپوزیت دندانی

Statement of Problem: The relatively poor wear resistance of dental composite in stress bearing posterior situations has restricted wider clinical application of this restorative material. Purpose: The aim of this study was to evaluate the three body abrasive wear of a dental composite based on a new filler (leucite: KAl Si2O6) and to compare it with the wear resistance of a composite based on ...

متن کامل

Wear test combining simulated occlusal wear and toothbrush wear.

A new wear testing system, which carries out toothbrush wear and simulated occlusal wear tests alternately, was developed. Differences in wear behavior among three modes of wears, combined wear, toothbrush wear and simulated occlusal wear, were investigated using polymethylmethacrylate (PMMA) and two commercial resin composites (Z100, APX). The area of the material loss after each test was meas...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the mechanical behavior of biomedical materials

دوره 4 3  شماره 

صفحات  -

تاریخ انتشار 2011