Success rate of transvenous left ventricular lead implantation for cardiac resynchronisation therapy - recent experience of a single centre.

نویسندگان

  • Maciej Sterliński
  • Aleksander Maciag
  • Ilona Kowalik
  • Michał Lewandowski
  • Dariusz Zajac
  • Paweł Syska
  • Cezary Sosnowski
  • Andrada Labecka
  • Krzysztof Kuśmierski
  • Mariusz Pytkowski
  • Hanna Szwed
چکیده

BACKGROUND Implantation of a left ventricular (LV) lead for cardiac resynchronisation therapy (CRT) may be challenging. Wider use of various implantation techniques increases the success rate of CRT. AIM Short-term analysis of the success rate of transvenous LV lead implantation for CRT. METHODS All CRT procedures performed in 2009 with first-time LV lead implantation attempt were analysed in terms of efficacy, total number of procedures, procedure and fluoroscopy time, complications, and reinterventions. Final LV lead location and the number of tested sites were analysed. Complex procedures were defined and described. RESULTS We studied 122 patients aged 67.6 +/- 10.6 years (98 males/80%) selected for CRT. The CRT implantation was an upgrade procedure in 17 patients. Fifty-six (46%) patients had coronary artery disease and 111 (91%) patients were in NYHA class III. The mean LV ejection fraction was 27% (range 10-35%). The implantation success rate was 97.5%. There were 87 (73%) CRT-D systems implanted and 32 (27%) CRT-P systems. Mean procedure time was 118 +/- 41 min, and fluoroscopy time was 15.9 +/- 12.1 min. An optimal location of the LV lead was achieved in 107 (90%) patients. More than one LV lead sites were tested in 42 (35.3%) patients. Complex procedures were performed in 4 (3.4%) patients. Early LV lead reintervention (< 30 days) was necessary in 10 (8.4%) patients (11 procedures), and epicardial lead placement was performed in one patient. The LV lead location in the antero-lateral branch demonstrated the lowest reintervention rate (1/22, 4.5%) v. other sites (great cardiac vein: 1/8, 12.5%, lateral branches: 9/86, 10.5%, p = NS). The LV lead-related reinterventions and initial procedure failure were associated with the upgrade procedures. No serious periprocedural complications were recorded. In one patient, the CRT system was explanted due to pocket infection. One patent died three months after CRT implantation due to progressive end-stage congestive heart failure. CONCLUSIONS 1. In a tertiary centre, CRT implantation success rate is high and implantation procedures are safe. 2. Achieved LV lead location is optimal in a vast majority of patients. 3. We noted a significant rate of early reinterventions related to LV lead dislodgement. 4. The LV lead implantation failure and reinterventions occurred more frequently in subjects with upgrade- to-CRT procedures. A similar trend was also noted in patients after cardiac surgery. 5. In selected cases, advanced techniques must be used to achieve successful CRT implantation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Four years follow-up of epicardial left ventricular pacing by mini-thoracotomy for cardiac resynchronisation therapy in congestive heart failure (four cases).

BACKGROUND AND AIM To establish whether left ventricular (LV) pacing by mini-thoracotomy is a safe and feasible procedure after failed transvenous cardiac resynchronisation therapy (CRT), we described four cases of patients who demonstrated congestive heart failure (CHF), had transvenous LV lead implantation failures, and underwent a mini-left-lateral thoracotomy and implantation of an epicardi...

متن کامل

Implantable cardioverter-defibrillator in a patient with dextrocardia situs inversus

Background: Dextrocardia is a congenital anomaly, which may have coexistent coronary artery disease (CAD), arrhythmias and conventional indications for device therapy. However, the implantation of transvenous leads can be technically challenging and the approach needs to be tailored to the patient's individual anatomy. Case presentation: A 54-year-old male with dextrocardia situs inversus and i...

متن کامل

Percutaneous Extraction of Transvenous Permanent Pacemaker/Defibrillator Leads

BACKGROUND Widespread use of cardiovascular implantable electronic devices has inevitably increased the need for lead revision/replacement. We report our experience in percutaneous extraction of transvenous permanent pacemaker/defibrillator leads. METHODS Thirty-six patients admitted to our centre from September 2005 through October 2012 for percutaneous lead extraction were included. Lead re...

متن کامل

Contralateral transvenous left ventricular lead placement of implantable devices with pre-sternal tunnelling in chronically obstructed subclavian veins

Cardiac resynchronisation therapy (CRT) is a recognised therapy for the management of severe left ventricular dysfunction, advanced congestive cardiac failure (NYHA III or IV), ventricular dyssynchrony (either broad LBBB or mechanical dyssynchrony on echocardiography) and failure of optimal medical therapy to achieve improvement in clinical status. Upgrading right ventricular pacemakers or defi...

متن کامل

Surgical placement of left ventricular lead for cardiac resynchronisation therapy after failure of percutaneous attempt

OBJECTIVE Cardiac resynchronisation therapy has been shown to be an effective treatment to improve functional status and prolong survival of patients in advanced chronic heart failure. This study assessed the surgical outcomes of left anterior mini-thoracotomy for the implantation of left ventricular epicardial pacing leads in cardiac resynchronisation therapy. METHODS Our study consisted of ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Kardiologia polska

دوره 68 8  شماره 

صفحات  -

تاریخ انتشار 2010