Snare sheath versus evolution sheath in transvenous lead extraction.

نویسندگان

  • Jihua Kong
  • Yilun Tian
  • Fei Guo
  • Feng Ze
  • Jiangbo Duan
  • Long Wang
  • Xuebin Li
  • Jihong Guo
چکیده

Lead extraction remains a challenging procedure with significant success. Owing to the increasing use of cardiac implantable electronic devices, there is a growing need for effective techniques management, to avoid the occurrence of device-related complications and lead dysfunction. We made a comparison of Evolution sheath and Needles Eye Snare sheath (abbreviated to Snare sheath) by analyzed the results using two kind of the methods in the Cardiology Center of Peking University People's Hospital. In the retrospective study we evaluated patients who underwent lead extraction from July 2013 to July 2014. Those who underwent lead removal without using evolution or snare were excluded. Primary endpoints included total exposure time, operation time, and complications. Data on clinical characteristics, indications, and outcomes were prospectively collected and analyzed. A total of 76 patients were included in the study (65.8% male; aged 68.1±14.34 years old). Snare and Evolution were used in 59 and 17 patients, respectively. A total of 134 leads were removed with 103 leads (76.87%) extracted using the Snare sheath. Lead age was 10.8±7.0 years. Complete extraction was observed in 67 patients of 124 leads. Evolution sheath was associated with significantly lower complication even after adjustment of the number of leads, type of leads, and lead age, compared to the Snare group (P<0.05). In the Snare sheath group, mortality rate was 1.69% and minor complication rate was 3.39%. When compared to the Snare sheath, lead extraction with the Evolution sheath has less X-ray exposure time and less operation time (P<0.05), while with a higher success rate (P<0.05). Besides, the Evolution group has fewer major and minor complications.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Removal of a chronically implanted active-fixation coronary sinus pacing lead using the Cook Evolution(C) lead extraction sheath.

Case report An 80-year-old man with an implanted resynchronization therapy pacemaker device was referred to our institution in October 2011 to perform a transvenous lead and generator removal for a severe pocket infection. As left ventricular pacing lead, an unipolar activefixation coronary sinus (CS) lead (Attain StarFix 4195OTW,Medtronic Inc.), positioned in a lateral coronary vein, had been ...

متن کامل

Extraction of old pacemaker or cardioverter-defibrillator leads by laser sheath versus femoral approach.

BACKGROUND Some operators routinely extract chronically implanted transvenous leads from a femoral, whereas others prefer a superior approach. This prospective study compared the safety and effectiveness of laser sheaths versus femoral snare extractions. METHODS AND RESULTS The single-center study comprised 101 patients referred for unequivocal indications to extract > or =1 transvenous lead(...

متن کامل

Lead Extraction: "Drag Through" Technique

The goal of extraction techniques of chronic pacemaker and defibrillator leads is to present an approach that is successful in extracting all leads and minimizes or eliminates complications. To extract a chronically implanted intravascular device, the device must be separated from the encapsulating inflammatory tissue. Three ablation techniques are currently used: mechanical, laser and electros...

متن کامل

Transvenous extraction of a 26-year-old Accufix atrial lead using TightRail rotating dilator sheath.

With the increasing number of implanted pacemakers and implantable cardioverter defibrillators, removal is required more frequently. Presently described is the transvenous extraction of a 26-year-old Accufix atrial lead using a mechanical dilator sheath. A 50-year-old male patient was admitted to the clinic with a pacemaker pocket infection. The atrial lead was an Accufix Bipolar J-Atrial activ...

متن کامل

The details of an unusual “ghost” after transvenous lead extraction: Three-dimensional computed tomography analysis

Transvenous lead extraction (TLE) is performed to prevent deaths in patients with device infections. Intracardiac masses detected by echocardiography, i.e., "ghosts," are reported in 8% of patients after a TLE in retrospective studies and in 14% in prospective studies. We herein describe a case with unusual ghosts after a TLE. Three-dimensional computed tomography (3DCT) is useful for revealing...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • International journal of clinical and experimental medicine

دوره 8 11  شماره 

صفحات  -