Radial endobronchial ultrasound with a guide sheath for diagnosis of peripheral cavitary lung lesions: a retrospective study
نویسندگان
چکیده
BACKGROUND Radial endobronchial ultrasound with a guide sheath (EBUS-GS) has improved the diagnostic outcomes of peripheral lung lesions. However, to our knowledge, reports on the use of EBUS-GS for diagnosis of cavitary lesions are unavailable. Therefore, this study aimed to assess the effectiveness and safety of EBUS-GS for diagnosis of peripheral cavitary lung lesions (PCLLs). METHODS This study was a single-institution retrospective review of PCLLs examined by using EBUS-GS between July 2013 and October 2015. The diagnostic results of different EBUS-GS samples, including cytologic, histopathologic, and microbiologic samples, were analysed separately. RESULTS Of 696 radial EBUS procedures performed during the study period, 50 were performed for examination of PCLLs. The overall diagnostic yield for EBUS-GS was 80 % (40/50). Regarding 27 malignant lesions, the diagnostic yields for cytologic and histopathologic samples were 63.0 % (17/27) and 74.1 % (20/27), respectively. Regarding 23 benign lesions, the diagnostic yields for histopathologic and microbiologic samples were 69.6 % (16/23) and 47.8 % (11/23), respectively. Uni- and multivariate analyses indicated that the EBUS probe being within the lesion was the only factor significantly associated with increased diagnostic yield (odds ratio, 7.04; P = 0.03). Although pulmonary infection occurred after the procedure in 1 patient (2.0 %), no other complications, including pneumothorax or significant haemorrhage, were reported. CONCLUSION EBUS-GS was found to be an effective and safe procedure for diagnosis of PCLLs.
منابع مشابه
Radial Probe Endobronchial Ultrasound for Peripheral Pulmonary Lesions: Initial Experience in an Indian Tertiary Healthcare Centre
Introduction : Diagnosis of peripheral pulmonary nodules is confusing; therefore, an accurate and safe lung biopsy can prevent unnecessary invasive diagnostic procedures. This study soughtto study the diagnostic yield, sensitivity, specificity, and negative and positive predictive values (NPV and PPV) of radial probe endobronchial ultrasound (EBUS)-guided biopsy for peripheral pulmonary lesions...
متن کاملFluoroscopic-Guided Radial Endobronchial Ultrasound Without Guide Sheath For Peripheral Pulmonary Lesions: A Safe And Efficient Combination.
BACKGROUND Several guidelines recommend computed tomography scans for populations with high-risk for lung cancer. The number of individuals evaluated for peripheral pulmonary lesions (PPL) will probably increase, and with it non-surgical biopsies. Associating a guidance method with a target confirmation technique has been shown to achieve the highest diagnostic yield, but the utility of broncho...
متن کاملRadial endobronchial ultrasound in diagnosing peripheral lung lesions in a high tuberculosis setting
BACKGROUND Current data for the utility of radial endobronchial ultrasound (EBUS) in investigating peripheral lung lesions (PLLs) has been restricted to populations with low pulmonary tuberculosis (TB) incidence. The aim of this study was to assess the diagnostic utility of radial EBUS with guide sheath in the diagnosis of peripheral lung lesions in Singapore, a high TB incidence setting. MET...
متن کاملComplications with Endobronchial Ultrasound with a Guide Sheath for the Diagnosis of Peripheral Pulmonary Lesions.
BACKGROUND Diagnostic bronchoscopy has been considered as a safe and effective procedure. Endobronchial ultrasound with a guide sheath (EBUS-GS) for the diagnosis of peripheral pulmonary lesions (PPLs) is becoming a common procedure, but reports about its safety are missing. OBJECTIVES The aim of this study was to evaluate the safety profile of EBUS-GS for the diagnosis of PPLs. METHODS All...
متن کاملA new middle-range diameter bronchoscope with large channel for transbronchial sampling of peripheral pulmonary lesions.
OBJECTIVE Although the diagnostic yield of guided bronchoscopy for peripheral pulmonary lesions has improved to 70%, it is still low compared with transthoracic needle aspiration. We produced a new bronchoscope with middle-range diameter and large channel (BF-Y0053, Olympus, Japan), and evaluated its diagnostic efficacy for peripheral pulmonary lesions. METHODS This was a retrospective study ...
متن کامل