Control of active power for synchronization and transient stability of power grids

نویسندگان

  • Randall Martyr
  • Benjamin Schaefer
  • Christian Beck
  • Vito Latora
چکیده

As the energy transition transforms power grids across the globe it poses several challenges regarding grid design and control. In particular, high levels of intermittent renewable generation complicate the job of continuously balancing power supply and demand, which is necessary for the grid’s stability. Although there exist several proposals to control the grid, most of them have not demonstrated to be cost efficient in terms of optimal control theory. Here, we mathematically formulate the control problem for stable operation of power grids, determining the minimal amount of control in the active power needed to achieve the constraints, and minimizing a suitable cost function at the same time. We investigate the performance of the optimal control method with respect to the uncontrolled scenario and we compare it to a simple linear control case, for two types of external disturbances. Considering case studies with two and five nodes respectively, we find that the linear control can improve the synchronization and transient stability of the power grid. However, if the synchronized angular velocity after a disturbance is allowed to differ from its initial steady state value, the linear control performs inefficiently in comparison to the optimal one.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improvement of Transient Voltage Profile Using Power Control of the DFIG-Based Wind Farm Under Severe Voltage Dip Event

Improving transient voltage stability is one of the most important issues that must be provided by doubly fed induction generator (DFIG)-based wind farms (WFs) according to the grid code requirement. This paper proposes adjusted DC-link chopper based passive voltage compensator and modified transient voltage controller (MTVC) based active voltage compensator for improving transient voltage stab...

متن کامل

Optimal Intelligent Control of Plug-in Fuel Cell Electric Vehicles in Smart Electric Grids

In this paper, Plug-in Fuel Cell Electric Vehicle (PFCEV) is considered with dual power sources including Fuel Cell (FC) and battery Energy Storage. In order to respond to a transient power demand, usually supercapacitor energy storage device is combined with fuel cell to create a hybrid system with high energy density of fuel cell and the high power density of battery. In order to simulate the...

متن کامل

A Hybrid Control Method for Stable Operation of Active Power Filters in Three-Phase Four-Wire Networks

The main goal of this study is the use of Lyapunov’s stability theory to a three-phase four-wire shunt active power filter (SAPF), since this method has been applied effectively to other areas of converter. The dynamic model of the SAPF is first established, after that, a combination of fuzzy tracking control and Lyapunov function is suggested in order to impose a desired transient waveform on ...

متن کامل

DC Voltage Control and Power-Sharing of Multi-Terminal DC Grids Based on Optimal DC Power Flow and Flexible Voltage Droop Strategy

This paper develops an effective control framework for DC voltage control and power-sharing of multi-terminal DC (MTDC) grids based on an optimal power flow (OPF) procedure and the voltage-droop control. In the proposed approach, an OPF algorithm is executed at the secondary level to find optimal reference of DC voltages and active powers of all voltage-regulating converters. Then, the voltage ...

متن کامل

A New Approach for Reactive Power Control of Single Phase Transformerless Inverter to Modify Power Quality in Stand Alone Micro-Grids with Current Leakage Elimination

Nowadays there has been an increasing interest in transformerless inverter for grid-connected photovoltaic (PV) system due to low cost, high efficiency and light weight. One of the reasons describe the grid behavior is capability of reactive power control by inverter. According to the standard VDE-AR-N 4105, grid-tied PV inverter of power rating below 3.68KVA, should attain power factor (PF) fr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • CoRR

دوره abs/1802.06647  شماره 

صفحات  -

تاریخ انتشار 2018