Waveform analysis of biphasic external defibrillators.

نویسندگان

  • U Achleitner
  • K Rheinberger
  • B Furtner
  • A Amann
  • M Baubin
چکیده

BACKGROUND AND OBJECTIVE All internal defibrillators and some external defibrillators use biphasic waveforms. The study analysed the discharged waveform pulses of two manual and two semi-automated biphasic external defibrillators. METHODS AND RESULTS The defibrillators were discharged into resistive loads of 25, 50 and 100 Omega simulating the patient's transthoracic impedance. The tested biphasic defibrillators differed in initial current as well as initial voltage, varying from 10.9 to 73.3 A and from 482.8 to 2140.0 V, respectively. The energies of the manual defibrillators set at 100, 150 and 200 J deviated by up to +19.1 or -28.9% from the selected energy. Impedance-normalised delivered energy varied from 1.0 to 12.5 J/Omega. Delivered energy, shock duration and charge flow were examined with respect to the total pulse, its splitting into positive and negative phases and their impedance dependence. For three defibrillators pulse duration increased with the resistive load, whereas one defibrillator always required 9.9 ms. All tested defibrillators showed a higher charge flow in the positive phase. Defibrillator capacitance varied between approximately 200 and 100 mu F and internal resistance varied from 2.0 to 7.6 Omega. Defibrillator waveform tilt ranged from -13.1 to 61.4%. CONCLUSIONS The tested defibrillators showed remarkable differences in their waveform design and their varying dependence on transthoracic impedance.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transthoracic incremental monophasic versus biphasic defibrillation by emergency responders (TIMBER): a randomized comparison of monophasic with biphasic waveform ascending energy defibrillation for the resuscitation of out-of-hospital cardiac arrest due to ventricular fibrillation.

BACKGROUND Although biphasic, as compared with monophasic, waveform defibrillation for cardiac arrest is increasing in use and popularity, whether it is truly a more lifesaving waveform is unproven. METHODS AND RESULTS Consecutive adults with nontraumatic out-of-hospital ventricular fibrillation cardiac arrest were randomly allocated to defibrillation according to the waveform from automated ...

متن کامل

Multicenter comparison of truncated biphasic shocks and standard damped sine wave monophasic shocks for transthoracic ventricular defibrillation. Transthoracic Investigators.

BACKGROUND The most important factor for improving out-of-hospital ventricular fibrillation survival rates is early defibrillation. This can be achieved if small, lightweight, inexpensive automatic external defibrillators are widely disseminated. Because automatic external defibrillator size and cost are directly affected by defibrillation waveform shape and because of the favorable experience ...

متن کامل

Multicenter, Randomized, Controlled Trial of 150-J Biphasic Shocks Compared With 200- to 360-J Monophasic Shocks in the Resuscitation of Out-of-Hospital Cardiac Arrest Victims

Background—In the present study, we compared an automatic external defibrillator (AED) that delivers 150-J biphasic shocks with traditional high-energy (200to 360-J) monophasic AEDs. Methods and Results—AEDs were prospectively randomized according to defibrillation waveform on a daily basis in 4 emergency medical services systems. Defibrillation efficacy, survival to hospital admission and disc...

متن کامل

Importance of using biphasic shock waveforms for cardioversion from atrial fibrillation: an unresolved issue.

Correspondence to: Dr John M Morgan, Southampton University Hospitals, Southampton, SO16 6UY, UK; jmm@ cardiology.co.uk . . . . . . . . . . . . . . . . . . . . . . . I n a previous issue of Heart, Scholten and colleagues presented data to show that a biphasic external atrial defibrillation shock waveform offers no significant advantage over a monophasic shock waveform in current clinical practi...

متن کامل

Comparison of outcomes after use of biphasic or monophasic defibrillators among out-of-hospital cardiac arrest patients: a nationwide population-based observational study.

BACKGROUND The use and popularity of the biphasic waveform defibrillator as a replacement for the monophasic waveform defibrillator are increasing, but it is unclear whether this can improve the rate of survival among out-of-hospital cardiac arrest patients. This study aimed to verify the hypothesis that the outcome of out-of-hospital cardiac arrest patients who received defibrillation shock wi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Resuscitation

دوره 50 1  شماره 

صفحات  -

تاریخ انتشار 2001