Separation of oligonucleotides with single-base mutation by capillary electrophoresis using specific interaction of metal ion with nucleotide.
نویسندگان
چکیده
A unique tactic for the separation of single-base sequential isomers of oligomeric single-stranded DNA by a CE separation system employing the specific interaction of metal ion with nucleotide was demonstrated, enabling the separation of the mixture of a 12-mer oligonucleotide and its single-base mutants, as well as their positional isomers.
منابع مشابه
Chiral Separation of Basic and Zwitterionic Drugs by Highly Sulfated Cyclodextrins Using Short-End Injection Capillary Electrophoresis Highly Sulfated Cyclodextrins Using Short-End Injection Capillary Electrophoresis
Due to high resolution power of sulfated cyclodextrins (HS-CDs), utilization of these selectors for chiral resolution of 7 basic and 2 zwitterionic drugs have been examined. Experiments were performed on a HP3DCE instrument equipped with an on-column diode array UV absorbance detector. Fused silica capillaries with an inner diameter of 50 ?m, an outer diameter of 365 ?m, and a total length of 4...
متن کاملChiral Separation of Basic and Zwitterionic Drugs by Highly Sulfated Cyclodextrins Using Short-End Injection Capillary Electrophoresis Highly Sulfated Cyclodextrins Using Short-End Injection Capillary Electrophoresis
Due to high resolution power of sulfated cyclodextrins (HS-CDs), utilization of these selectors for chiral resolution of 7 basic and 2 zwitterionic drugs have been examined. Experiments were performed on a HP3DCE instrument equipped with an on-column diode array UV absorbance detector. Fused silica capillaries with an inner diameter of 50 ?m, an outer diameter of 365 ?m, and a total length of 4...
متن کاملDetection of Single-base Mutation by Affinity Capillary Electrophoresis in a Pdms-glass Hybrid Microdevice
An extremely rapid on-chip separation of DNA from its single-base substituted mutant is described. By using affinity capillary electrophoresis (ACE) in a poly(dimethylsiloxane) (PDMS)-glass hybrid microdevice, we achieved the separation within 5 s.
متن کاملEffect of Capillary Rinsing Protocol on the Reproducibility of Separation in Capillary Electrophoresis with Indirect UV Detection
Capillary electrophoresis (CE) with indirect UV detection is an interesting analytical method for the analysis of drugs and pharmaceuticals. Good and reproducible capillary quality is needed to develop robust methods and to facilitate method transfer in CE. It is widely accepted that preconditioning procedures are indispensable in capillary electrophoresis in order to achieve reproducibility of...
متن کاملEffect of Capillary Rinsing Protocol on the Reproducibility of Separation in Capillary Electrophoresis with Indirect UV Detection
Capillary electrophoresis (CE) with indirect UV detection is an interesting analytical method for the analysis of drugs and pharmaceuticals. Good and reproducible capillary quality is needed to develop robust methods and to facilitate method transfer in CE. It is widely accepted that preconditioning procedures are indispensable in capillary electrophoresis in order to achieve reproducibility of...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Analyst
دوره 134 7 شماره
صفحات -
تاریخ انتشار 2009