Monte Carlo simulation of electron - solid interactions in cement - based materials
نویسنده
چکیده
6 7 Knowledge of the size of the electron-solid interaction volume and the sampling volume of various signals 8 within it is important for interpretation of images and analytical results obtained from electron microscopy. In 9 this study we used a Monte Carlo technique to simulate electron trajectories in order to investigate the shape and 10 size of the interaction volume, the spatial and energy distribution of backscattered electrons and characteristic x11 rays in cement-based materials. We found that the maximum penetration depth of the electron trajectories ranges 12 from 0.75 to 1.5μm at 10keV and from 2.5 to 5.0μm at 20keV. For backscattered electrons, the maximum 13 sampling depth is about 30% of the interaction volume depth and its lateral dimension is close to the interaction 14 volume depth. The sampling volume size of characteristic x-rays is a substantial fraction of the interaction 15 volume. For ettringite, the amount of material analysed in x-ray microanalysis is in the order of 1 to 100μm at 16 conventional SEM accelerating voltages of 10 to 20keV. 17
منابع مشابه
Evaluation of Electron Contamination in Cancer Treatment with Megavoltage Photon Beams: Monte Carlo Study
Background: Megavoltage beams used in radiotherapy are contaminated with secondary electrons. Different parts of linac head and air above patient act as a source of this contamination. This contamination can increase damage to skin and subcutaneous tissue during radiotherapy. Monte Carlo simulation is an accurate method for dose calculation in medical dosimetry and has an important role in opt...
متن کاملDesign and Simulation of Photoneutron Source by MCNPX Monte Carlo Code for Boron Neutron Capture Therapy
Introduction Electron linear accelerator (LINAC) can be used for neutron production in Boron Neutron Capture Therapy (BNCT). BNCT is an external radiotherapeutic method for the treatment of some cancers. In this study, Varian 2300 C/D LINAC was simulated as an electron accelerator-based photoneutron source to provide a suitable neutron flux for BNCT. Materials and Methods Photoneutron sources w...
متن کاملThe study of neutron interactions with soft tissue using Monte Carlo simulation using the source PF
The most important part of neutron therapy treatment (NCT1) is to achieve a beam of neutrons with suitable energy and intensity, as well as the least pollution and damage. In this study, in order to correct the neutron spectrum from D-D fusion and its use in neutron therapy, a set of different materials which are called the Beam Shaping Assembly (BSA) was placed in the direction of energy 2.45 ...
متن کاملLocalization of electron virtual SSD in a Siemens-Primus linear accelerator: Comparison of measurements with Monte Carlo simulation
Introduction: Because of importance of impact of the Source to Surface Distance (SSD) in determining of monitor unit for electron-therapy, it is essential to know the Virtual Source Position (VSP) for electron beam for a linear therapeutic accelerator for each energy and field size. , especially using the Khan method (photo distance squared method) And compare the results with...
متن کاملA Monte Carlo simulation study on the effectiveness of electron filters designed for telecobalt radiation therapy treatment
Background: The aim of present study was to analyze the effectiveness of electron filters in the Telecobalt radiotherapy treatment by simulation technique. Materials and Methods: The BEAMnrc Monte Carlo code was used to simulate the electron filters of thickness of 0.5 gm/cm2 below the trimmer bar for 35 × 35 cm2 field size in Theratron Equinox-80 telecobalt unit. The electron filters were mad...
متن کامل