Effects of humidification on nasal symptoms and compliance in sleep apnea patients using continuous positive airway pressure.

نویسندگان

  • C A Massie
  • R W Hart
  • K Peralez
  • G N Richards
چکیده

STUDY OBJECTIVES To evaluate the effects of humidification on nasal symptoms and compliance in sleep apnea patients using continuous positive airway pressure (CPAP). DESIGN A randomized, crossover design was employed. SETTING The study was conducted at two suburban community-based hospital sleep laboratories. PATIENTS Data were collected on 38 obstructive sleep apnea patients (mean age, 44.1 years) in whom CPAP was a novel treatment. INTERVENTIONS The interventions were heated humidity, cold passover humidity, and a washout period without humidity. MEASUREMENTS AND RESULTS Patients were titrated with heated humidity or cold passover humidity in the laboratory and subsequently initiated on humidity. Objective compliance, self-report of factors affecting CPAP use, satisfaction with CPAP, feeling upon awakening, and daytime sleepiness were assessed at the completion of each 3-week treatment period and a 2-week washout period. Outcome measures were assessed with one-way analysis of variance followed by Scheffe post hoc comparisons. Significant main effects were observed for compliance (F2,37 = 5.2; p = 0.008), satisfaction with CPAP (F2,37 = 4.5; p = 0.01), and feeling refreshed on awakening (F2,37 = 4.4; p = 0.02). A significant decrease in daytime sleepiness was observed between baseline and each of the conditions (F3,37 = 55.5; p<0.0001), but Epworth sleepiness scale scores did not differ between conditions (all p values >0.56). CPAP use with heated humidity (5.52+/-2.1 h/night) was greater than CPAP use without humidity (4.93+/-2.2 h/night; p = 0.008). Compliance differences were not observed between CPAP use with cold passover humidity and CPAP use without humidity. Patients were more satisfied with CPAP when it was used with heated or cold passover humidity (p< or =0.05). However, only heated humidity resulted in feeling more refreshed on awakening (p<0.05). No significant differences were observed among the three groups on the global adverse side effect score (F2,37 = 2.5; p = 0.09). Specific side effects such as dry mouth or throat and dry nose were reported less frequently when CPAP was used with heated humidity compared to CPAP use without humidity (p<0.001). CONCLUSIONS Compliance with CPAP is enhanced when heated humidification is employed. This is likely due to a reduction in side effects associated with upper airway symptoms and a more refreshed feeling upon awakening. Compliance gains may be realized sooner if patients are started with heated humidity at CPAP initiation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of heated humidification on compliance and quality of life in patients with sleep apnea using nasal continuous positive airway pressure.

STUDY OBJECTIVE To determine whether the addition of heated humidification at treatment initiation with nasal continuous positive airway pressure (CPAP) would lead to better CPAP compliance and improve quality of life and subjective sleepiness in patients with sleep apnea. DESIGN Randomized controlled trial. SETTING An academic sleep center located at a Veterans Affairs hospital. PATIENTS...

متن کامل

Humidified nasal continuous positive airway pressure in obstructive sleep apnoea.

Heated humidification of nasal continuous positive airway pressure (nCPAP) reduces upper airway symptoms and improves initial use in obstructive sleep apnoea syndrome (OSAS). The present study aimed to assess the effect of heated humidification of nCPAP on upper airway symptoms and initial use in obstructive sleep apnoea. This study was of a randomised, crossover design. Subjects with polysomno...

متن کامل

Use of heated humidification during nasal CPAP titration in obstructive sleep apnoea syndrome.

Nasal symptoms associated with the use of nasal continuous positive airway pressure (nCPAP) in obstructive sleep apnoea (OSA) can adversely impact on patients' tolerance, acceptance and adherence to nCPAP therapy. Regular use of heated humidification is effective in alleviating these symptoms and improve patient comfort. In a randomised, parallel, double-blinded, controlled study, the present a...

متن کامل

Interventions to improve compliance in sleep apnea patients previously non-compliant with continuous positive airway pressure.

STUDY OBJECTIVES Despite widespread agreement that continuous positive airway pressure is effective therapy for obstructive sleep apnea, it is estimated that 50% of patients recommended for therapy are noncompliant 1 year later. Interventions to improve compliance in such patients have not been studied. We evaluated a 2 phase intervention program to improve compliance in sleep apnea patients pr...

متن کامل

Nasal inflammation in sleep apnoea patients using CPAP and effect of heated humidification.

Nasal continuous positive airway pressure (CPAP) can cause undesirable nasal symptoms, such as congestion to obstructive sleep apnoea (OSA) patients, whose symptoms can be attenuated by the addition of heated humidification. However, neither the nature of nasal symptoms nor the effect of heated humidification on nasal pathophysiology and pathology are convincingly known. 20 patients with OSA on...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chest

دوره 116 2  شماره 

صفحات  -

تاریخ انتشار 1999