In situ, High-Resolution Measurement of Dissolved Sulfide Using Diffusive Gradients in Thin Films with Computer-Imaging Densitometry.

نویسندگان

  • P R Teasdale
  • S Hayward
  • W Davison
چکیده

The technique of diffusive gradients in thin films (DGT) has been developed for the measurement of dissolved sulfide. Sulfide species from the sampled waters diffuse through a polyacrylamide hydrogel and then react with pale yellow AgI((s)), incorporated at the surface of a second gel, to form black Ag(2)S((s)). The accumulated sulfide can be measured with a conventional purge-and-trap method followed by colorimetry (methylene blue). This enables the dissolved-sulfide concentration to be calculated under suitable conditions. Alternatively, the color change in the accumulating gel can be used to measure sulfide. A conventional flat-bed scanner, allied to imaging software, provided a densitometric measurement that was quantitatively related to the amount of sulfide accumulated. DGT measurements on synthetic solutions accurately determined the sulfide concentration (95% recovery), thereby confirming the unobstructed diffusion of HS(-) through the gel. The accumulated mass was inversely proportional to the diffusion-layer thickness as theoretically predicted. With the selected geometry, the limit of detection of the densitometric procedure for a 24-h deployment was 0.13 μmol L(-)(1), and the maximum concentration measurable was 60 μmol L(-)(1). When used in anoxic lacustrine waters, DGT provided sensible concentrations. It was also used to measure depth profiles at submillimeter resolution in estuarine surface sediments.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measuring sulfide accumulation in diffusive gradients in thin films by means of purge and trap followed by ion-selective electrode.

A procedure for measuring in situ sulfide concentrations by coupling diffusive gradients in thin films (DGT) to solid-state ion-selective electrodes (ISE) is described and evaluated. Laboratory tests were performed to evaluate the coupling of these techniques, and these results were compared to the previously used methods of computer imaging densitometry (CID) and methylene blue. An average elu...

متن کامل

William Davison (Ed.): Diffusive gradients in thin-films for environmental measurements.

accumulation, 71, 110, 111 non-ideal, 81 agarose, 33, 35, 44 pore size, 59 alkalinity, 35, 176, 183 aluminium, 44, 67, 176, 238 ammonia, 35, 176 ammonium persulphate, 33, 266 analytical techniques, 285 colorimetry, 181–182 computer imaging densitometry (CID), 181–182, 185, 202, 285 hyperspectral imaging, 182 laser ablation – ICPMS, 185–188, 285 PIXE, 175, 176 antimony, 44, 67, 135 area of windo...

متن کامل

Optimization of colorimetric DET technique for the in situ, two-dimensional measurement of iron(II) distributions in sediment porewaters.

The recently developed colorimetric diffusive equilibration in thin films (DET) technique for the in situ, high-resolution measurement of iron(II) in marine sediments is optimized to allow measurement of the higher iron concentrations typical of freshwater sediment porewaters. Computer imaging densitometry (CID) is used to analyze the retrieved samplers following exposure to ferrozine, a colori...

متن کامل

Gel for Simultaneous Chemical Imaging of Anionic and Cationic Solutes Using Diffusive Gradients in Thin Films

We report on a novel gel based on diffusive gradients in thin films (DGT) for the simultaneous measurement of cations and anions and its suitability for high resolution chemical imaging by using laser ablation inductively coupled plasma mass spectrometry (LA-ICPMS). The new high resolution mixed binding gel (HR-MBG) is based on zirconium-hydroxide and suspended particulate reagent-iminodiacetat...

متن کامل

High-Resolution Profiles of Dissolved Reactive Phosphorus in the Porewaters of Lake Sediments Assessed by DGT Technique

The technique of DGT (diffusive gradients in thin films) was applied to obtain high-resolution vertical profiles of dissolved reactive phosphorus (DRP) in sediment porewater of Lake Chaohu, a shallow eutrophication lake. Three kinds of DGT probes (with three thicknesses of diffusive gel: 0.38 mm, 0.78 mm and 1.18 mm) measured vertical concentration and induced flux from solid to solution phase ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical chemistry

دوره 71 11  شماره 

صفحات  -

تاریخ انتشار 1999