A low-noise thermistor bridge for use in calorimetry.

نویسندگان

  • R L Berger
  • W S Friauf
  • H E Cascio
چکیده

A precision thermistor bridge and thermistor is described for use ina thermaltitration calorimeteror a high-speed stoppedor continuous-flow calorimeter of the Roughton type. These are compared and evaluated with regard to several other types of detectors, including the platinum resistance thermometer, thermocouple, transistor thermometer, and capacitance thermometers. At this time the best detection for our purpose seems to be a specially constructed 20100 kfI thermistor used in conjunction with a new ac lock-in amplifier bridge. The sensitivity of the system is equivalent to a peak-to-peak noise of 25 X 106 #{176}C, witha 100-ms time constant and 1 W power dissipation in the thermistor. Long-term drift of the bridge, without an oven, was 1 X 10-6 #{176}C/min.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Glycylglycylglycine as a synthetic standard for serum protein determination.

s of Papers II. ANALYTICAL SYSTEMS 1003 A Small Portable Centrifugal Fast Analyzer System Charles D. Scott, Carl A. Burtis, Wayne F. Johnson, Louis H. Thacker, and Thomas 0. Tiffany 1009 A Low-Noise Thermistor Bridge for Use in Calorimetry Robert L. Berger, Walter S. Friauf, and Horace E. Cascio 1013 Thermal Titration: Application of Calorimetry to the Study of Plasma Coagulation D. Watt, R. L....

متن کامل

A New Structure for Direct Measurement of Temperature Based on Negative Temperature Coefficient Thermistor and Adaptive Neuro-fuzzy Inference System

Thermistors are very commonly used for narrow temperature-range high-resolution applications, such as in medicine, calorimetry, and near ambient temperature measurements. In particular, Negative Temperature Coefficient (NTC) thermistor is very inexpensive and highly sensitive, whose sensing temperature range and sensitivity are highly limited due to the intrinsic nonlinearity and self-heating p...

متن کامل

Measurement and comparison of the temperature-dependence of refractive index of water and Plexiglas phantoms by interferometry method for their use in optical calorimetry

In radiation calorimetry by using laser beams and interferometry setups, variations induced by dose absorption in phantom can be precisely measured. Dose absorption and the induced temperature change result in refractive index variation of the material. In order to be able to measure the low amount of absorbed dose in the phantom, temperature dependence of refractive index of the material must ...

متن کامل

An Experimental Investigation of Enclosure’s Effect on Noise Reduction in Portable Generators (Technical Note)

The portable generators are the main means of compensating the shortage of national electricity power as in Iraq. However, their noise causes a huge disturbance, uncomforting and loss of concentration of the nearby resident. This problem requires a solution because most shops and residential houses use generators. Covering method is a simple and relatively low cost one for reduction of generato...

متن کامل

Proposal of a new structural thermal vacuum sensor with diode-thermistors combined with a micro-air-bridge heater

A new structure thermal vacuum sensor with two pn junction diodes, Th-A and Th-B, as a high sensitive temperature sensor working like a thermistor and a micro heater formed on a micro air‒bridge is proposed. The micro air‒bridge is separated into two regions of A and B. The Th-A measures the temperature of the micro-heater formed on the region A and the Th-B does that of the region B which is c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 20 8  شماره 

صفحات  -

تاریخ انتشار 1974