Stiffness-matched segmented metallic guidewire for interventional cardiovascular MRI

نویسندگان

  • Burcu Basar
  • Adrienne E Campbell-Washburn
  • Toby Rogers
  • Merdim Sonmez
  • Anthony Z Faranesh
  • Kanishka Ratnayaka
  • Robert J Lederman
  • Ozgur Kocaturk
چکیده

Background Conductive guidewires and intravascular catheters are at risk of RF-induced heating under MRI [1]. Heating is found predominantly at the tip of conductive wires [2], and is modulated by wire diameter, length and insulation thickness [3]. Non-conductive materials, such as polymer, impart unsatisfactory mechanical properties on guidewires in terms of flexibility, stiffness, and torquability, for navigating tortuous cardiovascular structures and for safely delivering catheter devices.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Segmented nitinol guidewires with stiffness-matched connectors for cardiovascular magnetic resonance catheterization: preserved mechanical performance and freedom from heating

BACKGROUND Conventional guidewires are not suitable for use during cardiovascular magnetic resonance (CMR) catheterization. They employ metallic shafts for mechanical performance, but which are conductors subject to radiofrequency (RF) induced heating. To date, non-metallic CMR guidewire designs have provided inadequate mechanical support, trackability, and torquability. We propose a metallic g...

متن کامل

An Active Two Channel Guidewire for Interventional Cardiovascular Mri

INTRODUCTION The success and safety of interventional magnetic resonance imaging (iMRI) procedures require conspicuous intravascular instruments that can be distinguished from surrounding tissues. iMRI guidewires must navigate diseased tortuous structures without damaging them and while retaining mechanical integrity. The device tip is most likely to injure, disrupt, or perforate diseased tissu...

متن کامل

MRI active guidewire with an embedded temperature probe and providing a distinct tip signal to enhance clinical safety

BACKGROUND The field of interventional cardiovascular MRI is hampered by the unavailability of active guidewires that are both safe and conspicuous. Heating of conductive guidewires is difficult to predict in vivo and disruptive to measure using external probes. We describe a clinical-grade 0.035" (0.89 mm) guidewire for MRI right and left heart catheterization at 1.5 T that has an internal pro...

متن کامل

Positive contrast spiral imaging of a nitinol guidewire

Background The clinical translation of MRI-guided cardiovascular catheterization has been limited by the unavailability of devices that are both visible and safe under MRI. In particular, rigid metallic guidewires are essential for most catheterization procedures and are at risk of heating during MR imaging [1]. Here we present an MRI method that simultaneously improves the visualization of com...

متن کامل

Magnetic resonance imaging-guided catheter interventions in congenital heart disease.

Magnetic resonance imaging (MRI) has long been recognized as a useful technique for guiding diagnostic and therapeutic procedures. Biopsies have been guided by MRI since the 1980s1; neurosurgery followed soon thereafter.2 Excellent soft tissue contrast and accurate spatial localization and display in 3 dimensions were particular advantages of MRI over other modalities in neurological and body i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2015