Effect of using 2 throat swabs vs 1 throat swab on detection of group A streptococcus by a rapid antigen detection test.
نویسندگان
چکیده
OBJECTIVE To assess the effect of using 2 throat swabs vs 1 on rapid detection of group A streptococcus by the STREP A OIA MAX (hereafter, OIA MAX) test. METHODS Children aged 5 to 18 years with acute pharyngitis were randomized to 1 of 2 study groups. In group 1, one throat swab was obtained, streaked first on sheep blood agar, and then used for OIA MAX testing. In group 2, two throat swabs were obtained simultaneously. One swab was streaked first on sheep blood agar and then joined with the other swab for OIA MAX testing. In both groups, the pledgets in the collection-transport tube were incubated in Todd-Hewitt broth. A positive group A streptococcus culture either by sheep blood agar or Todd-Hewitt broth was confirmed by a latex agglutination test. RESULTS Three hundred sixty-three patients were enrolled, 177 in group 1 and 186 in group 2. Cultures were positive for group A streptococcus in 154 (42.4%) of 363 patients. The sensitivity and specificity of OIA MAX testing were 94.7% and 100.0%, respectively, in group 1, and 92.4% and 96.3%, respectively, in group 2. There was no statistical difference between the sensitivity, the specificity, and the predictive values of the OIA MAX test performed with 1 swab compared with those performed with 2 swabs (P>.10). There was no association between OIA MAX test sensitivity and the severity of pharyngitis as measured by the modified Centor criterion (history of fever, absence of cough, presence of pharyngeal or tonsillar exudates, and presence of cervical lymphadenopathy) scores. CONCLUSIONS The OIA MAX test yielded comparable sensitivity and specificity in both study groups. The use of 2 throat swabs instead of 1 swab did not increase the sensitivity of the OIA MAX test. The performance of the OIA MAX test did not depend on the severity of pharyngitis.
منابع مشابه
Comparison of LightCycler PCR, rapid antigen immunoassay, and culture for detection of group A streptococci from throat swabs.
We compared the performance characteristics of a real-time PCR method, the LightCycler Strep-A assay (Roche Applied Science, Indianapolis, Ind.), to those of a rapid antigen immunoassay, the Directigen 1-2-3 Group A Strep Test kit (BD Diagnostic Systems, Sparks, Md.), and a standard culture method for detection of group A streptococci (GAS) from 384 throat swabs. The LightCycler PCR produced mo...
متن کاملEfficacy of throat gargling for detection of group a beta-hemolytic streptococcus.
The purpose of our study was to investigate the suitability of throat gargling with sterile saline as an alternative method to throat swabs for detection of group A beta- hemolytic streptococcus (GAS). Throat specimens were obtained from 601 cases belonging to different age groups. Sterile Dacron swabs and gargle residue were first streaked on the side of a 5% sheep blood agar plate to which a ...
متن کاملDetection of group A streptococci in throat swabs by direct fluorometry.
A direct fluorometric test for the rapid detection of group A streptococci from throat swabs was compared with the microscopic fluorescent-antibody test. Formalinized throat swab cultures (490) were examined by the two methods, and the results agreed on 84% of the specimens. In another comparison, 15-hr broth cultures of 103 freshly taken throat swabs were tested by both methods. Of the specime...
متن کاملShort report: Can mouth swabs replace throat swabs? Cross-sectional survey of the effectiveness of rapid streptococcal swabs of the buccal mucosa.
• Les frottis de la muqueuse buccale utilisant un test rapide de détection d’antigènes se sont montrés inefficaces. Streptococcal sore throat—group A β−hemolytic streptococcal pharyngitis—accounts for 5% to 24% of patients complaining of sore throats, a frequent presentation in primary care.1 Several strategies for assessment of sore throat exist, including examination by a physician,1,2 sore t...
متن کاملNovel, rapid optical immunoassay technique for detection of group A streptococci from pharyngeal specimens: comparison with standard culture methods.
A novel immunoassay system based on the changes in the reflection of light, termed an optical immunoassay (OIA), was utilized to directly detect group A streptococcal (GAS) carbohydrate antigen from clinical specimens. In two studies, a total of 1,275 throat swabs were tested for the presence of this antigen with the Strep A OIA rapid detection system and the results were compared with those of...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Archives of pediatrics & adolescent medicine
دوره 159 5 شماره
صفحات -
تاریخ انتشار 2005