Evaluation of European Concerted Action on Anticoagulation lyophilized plasmas for INR derivation using the PT/INR line.

نویسندگان

  • Saied A Ibrahim
  • Jørgen Jespersen
  • Albert Pattison
  • Leon Poller
چکیده

The prothrombin time/international normalized ratio (PT/INR) Line method based on 5 certified European Concerted Action on Anticoagulation (ECAA) plasmas provides reliable local INR values without conventional World Health Organization international sensitivity index calibrations. The present study investigated the use of different numbers and types of ECAA calibrant plasmas to derive accurate PT/INR Lines and reliable INR values. The numbers ranged from 3 to 10 plasmas in a set with normal or abnormal samples. Sets were selected, and sampling was repeated 1,000 times for each center to derive PT/INR Lines. The lines were selected randomly or from clusters. The INR values of 5 independent "validation" plasmas were compared before and after correction. In 56 calibrations, 5 ECAA plasmas gave better results than did fewer plasmas. Plasmas with wide-ranging INR values gave better results than randomly selected sets, and including a normal plasma was not essential. The INR deviations of validation plasmas from certified values were reduced with sets of human, bovine/combined, and rabbit reagents. Deviations of more than 10% from certified INR values were significantly reduced (P < .001).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simplified method for international normalized ratio (INR) derivation based on the prothrombin time/INR line: an international study.

BACKGROUND The need to perform local International Sensitivity Index (ISI) calibrations and in particular the requirement for a manual method for prothrombin time (PT) determination, have proved to be obstacles to application of the WHO scheme for PT standardization. METHODS We used international normalized ratio (INR) derived with a set of only 5 European Concerted Action on Anticoagulation ...

متن کامل

European concerted action on anticoagulation. Quality assessment of the CoaguChek Mini and TAS PT-NC point-of-care whole-blood prothrombin time monitors.

BACKGROUND International Normalized Ratios (INRs) for prothrombin time obtained with the CoaguChek Mini and TAS (RapidPointCoag) PT-NC systems are markedly different and also differ from the "true" INR. There is therefore a need for local quality assessment (QA) of the two systems. METHODS A set of 60 lyophilized artificially depleted and 60 lyophilized coumarin plasmas were tested at 10 cent...

متن کامل

European Concerted Action on Anticoagulation (ECAA). An assessment of lyophilised plasmas for ISI calibration of CoaguChek and TAS whole blood prothrombin time monitors.

AIMS The recommended method for the international sensitivity index (ISI) calibration of whole blood point of care testing (POCT) prothrombin time (PT) systems was originally described by Tripodi et al in 1993 but is too complex and demanding. The present European Concerted Action on Anticoagulation (ECAA) study aimed to assess the reliability of simpler ISI calibration using lyophilised plasma...

متن کامل

The European Concerted Action on Anticoagulation (ECAA): field studies of coagulometer effects on the ISI of ECAA thromboplastins.

Local calibration studies have been performed with lyophilized plasmas at 155 European laboratories to assess coagulometer effects on manual ISI of ECAA thromboplastins (low ISI human recombinant and high ISI rabbit brain). Common sets of 7 normal and 20 artificially depleted lyophilized plasmas were tested with the thromboplastins in the routine local coagulometers. With the human reagent, mar...

متن کامل

Guidelines on preparation, certification, and use of certified plasmas for ISI calibration and INR determination--a rebuttal.

Reliable international normalized ratio (INR) determination depends on accurate values for international sensitivity index (ISI) and mean normal prothrombin time (MNPT). Local ISI calibration can be performed to obtain reliable INR. Alternatively, the laboratory may determine INR directly from a line relating local log(prothrombin time [PT]) to log(INR). This can be done by means of lyophilized...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of clinical pathology

دوره 135 5  شماره 

صفحات  -

تاریخ انتشار 2011