A Barbed Suture Repair For Flexor Tendons: A Novel Technique With No Exposed Barbs

نویسندگان

  • Cormac W. Joyce
  • Conor Sugrue
  • Jeffrey C. Chan
  • Luis Delgado
  • Dimitrios Zeugolis
  • Seam M. Carroll
  • Jack L. Kelly
چکیده

BACKGROUND Barbed suture technology has shown promise in flexor tendon repairs, as there is an even distribution of load and the need for a knot is eliminated. We propose that a quick and simple, novel, barbed technique without any exposed barbs on the tendon surface has comparable strength and a smaller cross-sectional area at the repair site than traditional methods of repair. METHODS Forty porcine flexor tendons were randomized to polybutester 4-strand barbed repair or to 4-strand Adelaide monofilament repair. The cross-sectional area was measured before and after repair. Biomechanical testing was carried out and 2-mm gap formation force, ultimate strength of repair, and method of failure were recorded. RESULTS The mean ultimate strength of the barbed repairs was 54.51 ± 17.9 while that of the Adelaide repairs was 53.17 ± 16.35. The mean 2-mm gap formation force for the barbed group was 44.71 ± 17.86 whereas that of the Adelaide group was 20.25 ± 4.99. The postrepair percentage change in cross-sectional area at the repair site for the Adelaide group and barbed group was 12.0 ± 2.3 and 4.6 ± 2.8, respectively. CONCLUSIONS We demonstrated that a 4-strand knotless, barbed method attained comparable strength to that of the traditional Adelaide repair technique. The barbed method had a significantly reduced cross-sectional area at the repair site compared with the Adelaide group. The 2-mm gap formation force was less in the barbed group than the Adelaide group. Barbed repairs show promise for tendon repairs; this simple method warrants further study in an animal model.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Flexor tendon repair: a comparative study between a knotless barbed suture repair and a traditional four-strand monofilament suture repair.

We compared the tensile strength of a novel knotless barbed suture method with a traditional four-strand Adelaide technique for flexor tendon repairs. Forty fresh porcine flexor tendons were transected and randomly assigned to one of the repair groups before repair. Biomechanical testing demonstrated that the tensile strengths between both tendon groups were very similar. However, less force wa...

متن کامل

A new barbed device for repair of flexor tendons.

We split 100 porcine flexor tendons into five groups of 20 tendons for repair. Three groups were repaired using the Pennington modified Kessler technique, the cruciate or the Savage technique, one using one new device per tendon and the other with two new devices per tendon. Half of the tendons received supplemental circumferential Silfverskiöld type B cross-stitch. The repairs were loaded to f...

متن کامل

Suture material for flexor tendon repair: 3–0 V-Loc versus 3–0 Stratafix in a biomechanical comparison ex vivo

BACKGROUND Barbed suture material offers the possibility of knotless flexor tendon repair, as suggested in an increasing number of biomechanical studies. There are currently two different absorbable barbed suture products available, V-Loc and Stratafix, and both have not been compared to each other with regard to flexor tendon repair. The purpose of this study was to evaluate both suture materi...

متن کامل

A Biomechanical Analysis of the Interlock Suture and a Modified Kessler-Loop Lock Flexor Tendon Suture

OBJECTIVE In this work, we attempted to develop a modified single-knot Kessler-loop lock suture technique and compare the biomechanical properties associated with this single-knot suture technique with those associated with the conventional modified Kessler and interlock suture techniques. METHODS In this experiment, a total of 18 porcine flexor digitorum profundus tendons were harvested and ...

متن کامل

A new modified Tsuge suture for flexor tendon repairs: the biomechanical analysis and clinical application

PURPOSE This study is to develop a new suturing technique for flexor tendon repair by modifying the extant Tsuge repair techniques and to use biomechanical analysis to compare the new method with four established repair techniques and evaluate its clinical efficacy in the repair of 47 flexor tendons in 22 patients. METHODS The biomechanical analysis relied on 50 flexor digitorum profundus ten...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2014