Midterm analysis of the seleXys cup with ceramic inlay

نویسندگان

  • Tamas Halasi
  • David Kieser
  • Christopher M.A. Frampton
  • Gary J. Hooper
چکیده

BACKGROUND Ceramic-on-ceramic (CoC) articulations in total hip replacement (THR) has been accepted as giving reliable mid-term results; however recent studies have reported higher revision rates of some implants. This study analyses the nationwide results of the seleXys TPS cup and the Bionit2 liner (Mathys, Bettlach, Switzerland) with respect to implant survival, cause for revision and mortality rates compared to other CoC articulations using the same stem. METHODS Utilising the New Zealand Joint Registry, we compared the seleXys TPS cup with Bionit2 liner used with an uncemented Twinsys femoral stem to every other uncemented CoC THR using the same stem. Multivariate analysis was used to determine the effects of patient age, gender, ASA score and implant head size on these rates. RESULTS Between 2006 and 2013 a total of 1035 seleXys THRs were performed on 862 patients. The comparison group had 375 THRs on 280 patients. There were 77 revisions (1.4/100 component years) in the study group and two in the comparison group (0.12/100 component years). Overall hazards ratio for revision was 12.22 times higher and female gender was associated with an increased risk (hazards ratio 1.77). Causes for revision were disturbing noises (23.4%), acetabular loosening (20.8%), and fracture of the liner (18.2%). Mortality rates were not significantly different (P = .567). CONCLUSIONS The seleXys TPS cup with the Bionit2 ceramic inlay coupling has an unacceptably high failure rate. We recommend avoiding this implant coupling and would advise that patients treated with this implant need close clinical and radiological follow-up.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of micro-leakage in class V ceramic inlay restorations cemented with two different resin cements

Comparison of micro-leakage in class V ceramic inlay restorations cemented with two different resin cements Dr. SM. Mousavinasab *- Dr. L. Pishevar * - Dr. T. Aghabeigi ** *Assistant Professor of Operative Dentistry Dept., Faculty of Dentistry, Shaheed Sadoughi Yazd University of Medical Sciences. ** Dentist Abstract Background and Aim: Resin cements are usually used for bonding ceramic inlays....

متن کامل

اثر زیرکونیا بر استحکام خمشی سرامیک IPS Empress 2

Background and Aim: All ceramic, inlay-retained resin bonded fixed partial denture is a conservative method for replacement of missing teeth, because of minimal tooth reduction. The connector between the retainer and the pontic is the weak point of these bridges. Reinforcement of ceramic core will increase the clinical longevity. The aim of this study was to determine the effect of zirconia on ...

متن کامل

Effect of ceramic thickness and composite bases on stress distribution of inlays--a finite element analysis.

The purpose of this study was to determine the effect of cavity depth, ceramic thickness, and resin bases with different elastic modulus on von Mises stress patterns of ceramic inlays. Tridimensional geometric models were developed with SolidWorks image software. The differences between the models were: depth of pulpal wall, ceramic thickness, and presence of composite bases with different thic...

متن کامل

Vertical marginal gap & retention of ceramic full coverage & inlay retained ceramic fixed partial dentures

Objectives: A comparison study between ceramic full coverage FPDs & 3 designs of ceramic inlay retained FPDs regarding vertical marginal gap & retention. Materials & Methods: Twenty samples were constructed and divided into 4 groups according to the type of restorations: full coverage, inlay-shaped (occluso-proximal inlay + proximal box), tub-shaped (occluso-proximal inlay), and proximal box-sh...

متن کامل

Fracture resistance of teeth restored with all-ceramic inlays and onlays: an in vitro study.

Fracture resistance of inlays and onlays may be influenced by the quantity of the dental structure removed and the restorative materials used. The purpose of this in vitro study was to evaluate the effects of two different cavity preparation designs and all-ceramic restorative materials on the fracture resistance of the tooth-restoration complex. Fifty mandibular third molar teeth were randomly...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2017