Interface pressures and shear stresses: sagittal plane angular alignment effects in three trans-tibial amputee case studies.

نویسندگان

  • J E Sanders
  • C H Daly
چکیده

Interface pressures and shear stresses at different sagittal plane angular alignment settings were measured on 3 trans-tibial amputee subjects ambulating with patellar-tendon-bearing total contact prostheses. Substantial socket-shank angular alignment modifications in the sagittal plane had minimal effect on stance phase peak interface pressures, though more substantial effects on stance phase peak resultant shear stresses. No consistent trend of a greater stress at misaligned vs nominally aligned settings was identified. Changes in interface stresses from session to session tended to be greater than those for different alignment settings, suggesting that subjects compensated well for misalignments but less well for session differences.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of sagittal plane prosthetic alignment on standing trans-tibial amputee knee loads.

The influence of sagittal plane prosthetic alignment changes on loads applied to the ispilateral knee was investigated using 5 transtibial amputee subjects. The goal was to determine which prosthetic alignment results in the most energy efficient standing and also minimises stresses on knee structures during standing. The electromyogram, the external mechanical loading of the prosthetic leg and...

متن کامل

Normal and shear stresses on a residual limb in a prosthetic socket during ambulation: comparison of finite element results with experimental measurements.

Interface stresses on a below-knee amputee residual limb during the stance phase of gait calculated using an analytical finite element model were compared with experimental interface stress measurements. The model was quasi-static and linear. Qualitatively, shapes of analytical and experimental interface stress waveforms were similar in that they were double-peaked with some distinct features a...

متن کامل

Clinical measurement of normal and shear stresses on a trans-tibial stump: characteristics of wave-form shapes during walking.

Stresses on the surface of a stump within a prosthetic socket during walking can potentially traumatize stump tissues. To gain insight into stresses and design parameters that affect them, normal and shear interface stresses were measured on three unilateral trans-tibial amputee subjects during walking trials. During stance phase repeated characteristics in wave-form shapes from different subje...

متن کامل

A new biomechanical method for determination of static prosthetic alignment.

A new static alignment method for trans-tibial prostheses is suggested using the individual load line as a reference. Standing posture and static alignment of 18 experienced trans-tibial prosthetic users with good walking ability were determined and compared with 20 healthy persons. The individual load line was defined by means of the new Otto Bock alignment system "L.A.S.A.R. Posture". The sag...

متن کامل

Changes in interface pressure and stump shape over time: preliminary results from a trans-tibial amputee subject.

Interface stresses and stump shape were measured during sessions over a two-month interval on a trans-tibial amputee subject. Results from thirteen transducer sites monitored during four sessions showed greater interface pressure changes over time at anterior sites than at lateral or posterior locations. There was a trend of decreased pressure with stump swelling and increased pressure for stum...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Prosthetics and orthotics international

دوره 23 1  شماره 

صفحات  -

تاریخ انتشار 1999