Anterior and Posterior Ocular Biometry in Healthy Chinese Subjects: Data Based on AS-OCT and SS-OCT
نویسندگان
چکیده
BACKGROUND To measure the anterior and posterior ocular biometric characteristics concurrently and to determine the relationship between the iris and choroid in healthy Chinese subjects. METHODS A total of 148 subjects (270 eyes) were enrolled in this cross-section study. The anterior and posterior ocular biometric characteristics were measured simultaneously by anterior segment optical coherence tomography (AS-OCT) and swept-source optical coherence tomography (SS-OCT). RESULTS Compared with male eyes, female eyes had narrower anterior biometric parameters that presented with smaller anterior segment parameters [including anterior chamber depth (ACD), width (ACW), area (ACA), and volume (ACV); (all p<0.001)], narrower anterior chamber angle parameters [including angle opening distance (AOD750), trabecular-iris space area (TISA750), and angle recess area (ARA); (all p<0.001)], higher iris curvature (ICURV) (p = 0.003), and larger lens vaults (LV) (p = 0.019). These anterior ocular biometric parameters were correlated with increasing age (p<0.01). Iris thickness (IT750) and iris area (IAREA) were associated with age, ACW, and pupil diameter (all p<0.05), while choroidal thickness (CT) was associated with age, gender, and axial length (all p<0.05). Univariate regression analysis showed that greater CT was significantly associated with smaller IAREA (p = 0.026). CONCLUSION Compared with male eyes, female eyes had narrower anterior biometric parameters that correlated with increasing age, which would be helpful in explaining the higher prevalence of angle closure rates in the female gender and in aging people. Increased CT might be associated with smaller iris area; however, this possibility needs to be investigated in future studies before this conclusion is made.
منابع مشابه
Reproducibility of a long-range swept-source optical coherence tomography ocular biometry system and comparison with clinical biometers.
OBJECTIVE To demonstrate a novel swept source optical coherence tomography (SS-OCT) imaging device using a vertical cavity surface-emitting laser (VCSEL) capable of imaging the full eye length and to introduce a method using this device for noncontact ocular biometry. To compare the measurements of intraocular distances using this SS-OCT instrument with commercially available optical and ultras...
متن کاملMeasurement of and Factors Associated with the Anterior Chamber Volume in Healthy Chinese Adults
Purpose. To measure the anterior chamber volume (ACV) and determine factors associated with the ACV in healthy Chinese adults. Methods. In this cross-sectional study, we used swept-source optical coherence tomography (SS-OCT) to measure ACV and other anterior segment parameters. Factors associated with ACV were also determined. Results. A total of 313 healthy Chinese adults were enrolled. The a...
متن کاملBiometry of the cornea and anterior chamber in chinese eyes: an anterior segment optical coherence tomography study.
PURPOSE. To investigate the normative data of corneal and anterior segment biometric parameters and their associations in Chinese adults, for use in preoperative assessment for corneal and anterior segment surgery. METHODS. This cross-sectional, population-based study included 750 subjects aged > or =50 years. The subjects underwent an ophthalmic examination including imaging with anterior segm...
متن کاملOcular anterior segment biometry and high-order wavefront aberrations during accommodation.
PURPOSE We investigated the relationships between the ocular anterior segment biometry and the ocular high-order aberrations (HOAs) during accommodation by combined ultralong scan depth optical coherence tomography (UL-OCT) and wavefront sensor. METHODS We enrolled 35 right eyes of young healthy subjects (21 women and 14 men; age, 25.6 ± 3.1 years; spherical equivalent refractive error, -0.41...
متن کاملComparison of Anterior Segment Optical Tomography Parameters Measured Using a Semi-Automatic Software to Standard Clinical Instruments
OBJECTIVE To compare anterior segment parameters measured using a semi-automatic software (Zhongshan Angle Assessment Program, ZAP) applied to anterior segment optical coherence tomography (AS-OCT) images, with commonly used instruments. METHODS Cross-sectional study of a total of 1069 subjects (1069 eyes) from three population-based studies of adults aged 40-80 years. All subjects underwent ...
متن کامل