Assessment of depth of anesthesia: PRST score versus bispectral index.
نویسندگان
چکیده
UNLABELLED Assessment of depth of anesthesia is the basis in anesthesiologists work because the occurrence of awareness during general anesthesia is important due to stress, which is caused in the patient at that moment, and due to complications that may arise later. There are subjective and objective methods used to estimate the depth of anesthesia. The aim of this study was to assess the depth of anesthesia based on clinical parameters and on the basis bispectral index, and determine the part of bispectral monitoring in support to clinical assessment. MATERIAL AND METHODS Sixty patients divided into two groups were analyzed in a prospective study. In first group (group 1), the depth of anesthesia was assessed by PRST score, and in the second group (group 2) was assessed by bispectral monitoring with determination PRST score concurrently. In both groups PRST score was assessed in four periods, while bispectral monitoring is used continuously. For analysis were used the BIS index values from the equivalent periods as PRST scores. PRST score value 0-3, and BIS index 40-60 were considered as adequate depth of anesthesia. The results showed that in our study were not waking patients during the surgery. In the group where the depth of anesthesia assessed clinically, we had a few of respondents (13%) for whom at some point were present indicators of light anesthesia. Postoperative interview excluded the possibility of intraoperative awareness. In the second group of patients and objective and clinical assessment indicated at all times to adequate depth of anesthesia. CONCLUSION The use of BIS monitoring with clinical assessment allows anesthesiologists precise decision-making in balancing and dosage of anesthetics and other drugs, as well as treatment in certain situations.
منابع مشابه
Impact of Bispectral Index Monitoring Versus Clinical Judgment as a Guide for Conduction of Anesthesia on Serum Cortisol Level in Co-ronary Artery Bypass Graft Surgery
Background: Inadequate depth of anesthesia leads to release of stress hormones. Electroencephalographic monitoring by bispectral index is a guide to asses the depth of anesthesia. The aim of the present study was to measure the serum cortisol levels as an index of stress response in patients who are candidates for coronary artery bypass graft surgery in two groups of patients. Methods: Seventy-...
متن کاملBispectral index monitoring during sedation with sevoflurane, midazolam, and propofol.
BACKGROUND Bispectral Index (BIS) has been used to measure sedation depth. Ideally, to guide anesthetic management, range of BIS scores at different sedation levels should not overlap, and BIS should be independent of drug used. This study assessed ability of BIS to predict sedation depth between sevoflurane, propofol, and midazolam. Quality of recovery was also compared. METHODS Patients und...
متن کاملValidation of the bispectral index monitor for measuring the depth of sedation in children.
The Bispectral Index (BIS) is an empirically calibrated number derived from adult electroencephalograph data that correlates with the depth of sedation in adults. We tested the hypothesis that the BIS score is a valid measure of the depth of pediatric sedation in a study designed to avoid limitations of a previously published report. BIS values from 96 healthy ASA physical status I-II children ...
متن کاملEvaluation of the Adequacy of General Anesthesia in Cesarean Section by Bispectral Index
Background: Awareness and recall, though not common, are the major hazards of general anesthesia, especially in Cesarean section (C/S) because of the absence of benzodiazepine and opioids for a significant time during anesthesia. In this study, the Bispectral Index (BIS), end-tidal isoflurane, and hemodynamic parameters were examined to evaluate the depth of the routine general anesthetic techn...
متن کاملCorrelation of bispectral index (BIS) monitoring and end-tidal sevoflurane concentration in a patient with lobar holoprosencephaly.
OBJECTIVE The bispectral index (BIS) is a parameter derived by electroencephalography (EEG) which provides a direct measurement of the effects of sedatives and anesthetics on the brain and offers guidance on the adequacy of anesthesia. The literature lacks studies on BIS monitoring in pediatric patients with congenital brain disease undergoing general anesthesia. CLINICAL FEATURES A 13-year-o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medicinski arhiv
دوره 65 4 شماره
صفحات -
تاریخ انتشار 2011