Comparison of different intubation techniques performed inside a moving ambulance: a manikin study.
نویسندگان
چکیده
OBJECTIVE. Airway management and endotracheal intubation may be required urgently when a patient deteriorates in an ambulance or aircraft during interhospital transfer or in a prehospital setting. The objectives of this study were: (1) to compare the effectiveness of conventional intubation by Macintosh laryngoscope in a moving ambulance versus that in a static ambulance; and (2) to compare the effectiveness of inverse intubation and GlideScope laryngoscopy with conventional intubation inside a moving ambulance. DESIGN. Comparative experimental study. SETTING. The experiment was conducted in an ambulance provided by the Auxiliary Medical Service in Hong Kong. PARTICIPANTS. A group of 22 doctors performed endotracheal intubation on manikins with Macintosh laryngoscope in a static and moving ambulance. In addition, they performed conventional Macintosh intubation, inverse intubation with Macintosh laryngoscope, and GlideScope intubation in a moving ambulance in both normal and simulated difficult airways. MAIN OUTCOME MEASURES. The primary outcome was the rate of successful intubation. The secondary outcomes were time taken for intubation, subjective glottis visualisation grading, and eventful intubation (oesophageal intubation, intubation time >60 seconds, and incisor breakage) with different techniques or devices. RESULTS. In normal airways, conventional Macintosh intubation in a static ambulance (95.5%), conventional intubation in a moving ambulance (95.5%), as well as GlideScope intubation in a moving ambulance (95.5%) were associated with high success rates; the success rate of inverse intubation was comparatively low (54.5%; P=0.004). In difficult airways, conventional Macintosh intubation in a static ambulance (86.4%), conventional intubation in a moving ambulance (90.9%), and GlideScope intubation in a moving ambulance (100%) were associated with high success rates; the success rate of inverse intubation was comparatively lower (40.9%; P=0.034). CONCLUSIONS. En-route intubation in an ambulance by conventional Macintosh laryngoscopy is superior to inverse intubation unless the cephalad access is impossible. GlideScope laryngoscopy appears to be associated with lower rates of eventful intubation in difficult airways and has better laryngoscopic view versus inverse intubation.
منابع مشابه
Comparison of the airway access skills of prehospital staff in moving and stationary ambulance simulation: A randomized crossover study☆
OBJECTIVES We aimed to compare the procedural success and intervention durations regarding various airway access skills in moving and stationary ambulance simulations. MATERIAL AND METHODS An ambulance simulator was used to simulate the moving ambulance environment, and a standard manikin was used for airway simulation. The study included 38 paramedics and paramedic students. In stationary an...
متن کاملAirway management in simulated restricted access to a patient - can manikin-based studies provide relevant data?
BACKGROUND Alternatives to endotracheal intubation (ETI) are required when access to the cranial end of the patient is restricted. In this study, the success rate and time duration of standard intubation techniques were compared with two different supraglottic devices. Two different manikins were used for the study, and the training effect was studied when the same manikin was repeatedly used. ...
متن کاملComparison of Indirect Video Laryngoscopes in Children Younger than Two Years of Age: a Randomized Trainee Evaluation Study.
BACKGROUND Gaining proficiency with various airway management tools is an important goal for anesthesiology training. Indirect video laryngoscopes facilitate tracheal intubation in adults, but it is not clear whether these findings translate to children. This study evaluates the total time to successful intubation when performed by anesthesiology trainees using GlideScope Cobalt® video laryngos...
متن کاملThe AirView Study: Comparison of Intubation Conditions and Ease between the Airtraq-AirView and the King Vision
We conducted a study assessing the quality and speed of intubation between the Airtraq with its new iPhone AirView app and the King Vision in a manikin. The primary endpoint was reduction of time needed for intubation. Secondary endpoints included times necessary for intubation. 30 anaesthetists randomly performed 3 intubations with each device on a difficult airway manikin. Participants had a ...
متن کاملComparison of direct intubation and Supraglottic Airway Laryngopharyngeal Tube (S.A.L.T.) for endotracheal intubation during cardiopulmonary resuscitation. Randomized manikin study.
BACKGROUND Airway control is a potentially lifesaving procedure, but intubation by direct laryngoscopy may be difficult. The aim of this study was to assess the success rate of tracheal intubation using the Macintosh laryngoscope and Supraglottic Airway Laryngopharyngeal Tube (S.A.L.T) device. METHODS This is a randomised cross-over study involving 120 paramedics utilising the Macintosh laryn...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Hong Kong medical journal = Xianggang yi xue za zhi
دوره 20 4 شماره
صفحات -
تاریخ انتشار 2014