Measurement of ERP latency differences: a comparison of single-participant and jackknife-based scoring methods.

نویسندگان

  • Andrea Kiesel
  • Jeff Miller
  • Pierre Jolicoeur
  • Benoit Brisson
چکیده

We used computer simulations to evaluate different procedures for measuring changes in the onset latency of a representative range of event-related components (the auditory and visual N1, P3, N2pc, and the frequency-related P3 difference wave). These procedures included several techniques to determine onset latencies combined with approaches using both single-participant average waveforms and jackknife-subsample average waveforms. In general, the jackknife-based approach combined with the relative criterion technique or combined with the fractional area technique (J.C. Hansen & S.A. Hillyard, 1980; S.J. Luck, 2005) provided the most accurate method and the greatest statistical power, with no inflation of Type I error rate.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Single- site and Multi-site Based Calibrations of SWAT in Taleghan Watershed, Iran

Calibration of model is critical for hydrologic modeling of large watersheds in a mountain watershed. In this study Soil and Water Assessment Tool (SWAT) used to comparison a single-site calibration procedure that employed streamflow measurement at outlet of watershed to a multi-site calibration method that used streamflow measurements at three stations (Galinak, Joestan and Dehdar). Results sh...

متن کامل

Comparison of p300 in risk-seeker and risk-averse people during simple gambling task

Risk preference, the degree of tendency to take risk, has a fundamental role at individual and social health and is divided to risk seeker and risk averse. Therefore, the study of neural corelates of risk preferences is essential at the field of psychology and psychiatry. The current study aimed to examine and compare an ERP component named P300 between subjects with different risk preferences....

متن کامل

Comparison of Double and Single Leg Weight-Bearing Radiography in Determining Knee Alignment

  Background: Knee malalignment is an important modifiable cause of osteoarthritis (OA). Surgical therapeutic procedures depend on proper knee alignment assessment. The purpose of this study was to compare knee alignment parameters between double and single leg weight-bearing radiographs and to evaluate the reproducibility of inter- and intra-observer measurements. Methods: One hundred eight p...

متن کامل

Technical Note: Performance measurement in industrial organizations, case study: Zarbal Complex

Industrial organizations are complex systems` where the interactions among the various functions such as Sales, Distribution, Manufacturing, Materials, Finance, Human Resources and Maintenance have to be man-aged towards a common purpose of delivering the customers satisfaction. However, since most of these or-ganizations have a `Functional Structure`, each function or department works towards ...

متن کامل

Comparison of Various Blood Pressure Measurement Techniques with Standard Office Based Blood Pressure Mesurement

Introduction: In order to control Hypertension, it is necessary to understand the methods of blood pressure measurement. Recent guidelines emphasize on employing appropriate blood pressure measurement techniques and white coat hypertension. Definition and methods of blood pressure measurement have changed in the American guideline based on SPRINT trial (Systolic Blood Pressure Intervention Tria...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Psychophysiology

دوره 45 2  شماره 

صفحات  -

تاریخ انتشار 2008