Comparison between Tendency-Oriented Perimetry (TOP) and octopus threshold perimetry.

نویسندگان

  • J Morales
  • M L Weitzman
  • M González de la Rosa
چکیده

OBJECTIVE To compare the results obtained by a new ultra-short automated perimetry test known as Tendency-Oriented Perimetry (TOP), which is an algorithm based on estimation of thresholds from information gathered from adjacent points with those obtained by a standard bracketing approach. TOP is designed to save up to 1/5 of the time taken by standard strategy by presenting each stimulus once on each location (instead of 4 to 6 times per location with the standard technique) and reaching a final threshold estimate by gathering information from responses to adjacent locations. DESIGN Prospective, multicenter, observational comparative case series. PARTICIPANTS/METHODS Four academic institutions provided data from testing 57 subjects, 15 with a normal ocular exam and 42 with a variety of visual field abnormalities. A total of 228 visual fields were analyzed. Two examinations of standard thresholding testing (Octopus program 32) and two examinations of the TOP program were obtained in each subject the same day. MAIN OUTCOME MEASURES Comparison of global indices such as mean deviation (MD), square root of loss of variance (sLV), topographical defects, point by point differences, reproducibility, sensitivity/specificity, and time required to complete the test. RESULTS Correlation coefficient of global indices between both tests was high, with mean deviation of r = 0.97 (SE[YX] +/- 1.65 decibels) and square root of loss variance of r = 0.93 (SE[YX] +/- 1.10 dB). Mean sensitivity tended to be 1 dB higher while MD tended to be 1 dB lower with TOP strategy. Reproducibility was equally good between both tests for threshold determination as well as for all global indices (MS, MD per quadrant, and LV). Cluster criteria for abnormality demonstrated TOP versus 32: sensitivity of 89/87; specificity of 90/77; positive predictive value of 96/91; negative predictive value of 75/68; and accuracy of 89/84. Mean time taken by this beta version of TOP was 4.05 minutes standard deviation +/- 0.55 versus the standard 32 version taking 14.65 minutes standard deviation +/- 3.75. CONCLUSIONS TOP was four times faster than the traditional full-threshold technique and was successful in detecting visual field abnormalities. Defects with TOP tended to be smaller, shallower, and with softer edges than with standard approach. TOP could prove an alternative to traditional perimetric techniques.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison between Threshold Pupil Perimetry and Suprathreshold Pupil Perimetry

Purpose: Pupil perimetry has so far been performed by the two following methods: suprathreshold perimetry during which the amplitude or ratio of pupil constriction is determined, and threshold perimetry during which the threshold of pupil reaction is determined. The authors compared the values obtained with these two methods using the modified Octopus 1-2-3. Subjects and methods: Pupil perimetr...

متن کامل

Perimetry Comparisons for Octopus G Top and Dynamic Programmes versus Humphrey 24-2 SITA Fast and SITA Standard Programmes

Aims: Previous comparisons of Octopus and Humphrey threshold programmes have shown differences, particularly for depth of defects. Recent developments have altered the Octopus background illumination. Thus, we sought to determine the subsequent extent of differences in results from commonly used central static programmes using Octopus and Humphrey perimeters. Study Design: Diagnostic accuracy s...

متن کامل

Comparison of Diagnostic Accuracy between Octopus 900 and Goldmann Kinetic Visual Fields

PURPOSE To determine diagnostic accuracy of kinetic visual field assessment by Octopus 900 perimetry compared with Goldmann perimetry. METHODS Prospective cross section evaluation of 40 control subjects with full visual fields and 50 patients with known visual field loss. Comparison of test duration and area measurement of isopters for Octopus 3, 5, and 10°/sec stimulus speeds. Comparison of ...

متن کامل

Automated combined kinetic and static perimetry: an alternative to standard perimetry in patients with neuro-ophthalmic disease and glaucoma.

OBJECTIVES To create a fully automated, combined perimetry program consisting of a static examination and a kinetic examination, and to compare the results of this test with standard static and kinetic visual fields (VFs). METHODS Fifty-six patients (74 eyes) undergoing neuro-ophthalmic or glaucoma evaluation who had standard static or kinetic perimetry examinations underwent the combined per...

متن کامل

Comparison of Octopus Semi-Automated Kinetic Perimetry and Humphrey Peripheral Static Perimetry in Neuro-Ophthalmic Cases

Aim. To compare semikinetic perimetry (SKP) on Octopus 900 perimetry to a peripheral static programme with Humphrey automated perimetry. Methods. Prospective cross-section study comparing Humphrey full field (FF) 120 two zone programme to a screening protocol for SKP on Octopus perimetry. Results were independently graded for presence/absence of field defect plus type and location of defect. Re...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Ophthalmology

دوره 107 1  شماره 

صفحات  -

تاریخ انتشار 2000