Reconstruction of Axial Tomographic High Resolution Data from Confocal Fluorescence Microscopy: A Method for Improving 3D FISH Images

نویسندگان

  • R. Heintzmann
  • G. Kreth
  • C. Cremer
چکیده

Fluorescent confocal laser scanning microscopy allows an improved imaging of microscopic objects in three dimensions. However, the resolution along the axial direction is three times worse than the resolution in lateral directions. A method to overcome this axial limitation is tilting the object under the microscope, in a way that the direction of the optical axis points into different directions relative to the sample. A new technique for a simultaneous reconstruction from a number of such axial tomographic confocal data sets was developed and used for high resolution reconstruction of 3D-data both from experimental and virtual microscopic data sets. The reconstructed images have a highly improved 3D resolution, which is comparable to the lateral resolution of a single deconvolved data set. Axial tomographic imaging in combination with simultaneous data reconstruction also opens the possibility for a more precise quantification of 3D data. The color images of this publication can be accessed from http://www.esacp.org/acp/2000/20-1/heintzmann.++ +htm. At this web address an interactive 3D viewer is additionally provided for browsing the 3D data. This java applet displays three orthogonal slices of the data set which are dynamically updated by user mouse clicks or keystrokes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High-resolution three-dimensional tomographic diffractive microscopy of transparent inorganic and biological samples.

We have developed a tomographic diffractive microscope, equipped with a fluorescence confocal scanner. We measure experimentally the lateral resolution using an edge method and by comparing tomographic images of the same samples with wide-field and laser scanning confocal microscopy images; a scanning electron microscope image serves as a reference. The experimental resolution is shown to be to...

متن کامل

Reconstruction of high-resolution fluorescence microscopy images based on axial tomography

For a reliable understanding of cellular processes, high resolution 3D images of the investigated cells are necessary. Unfortunately, the ability of fluorescence microscopes to image a cell in 3D is limited since the resolution along the optical axis is by a factor of two to three worse than the transversal resolution. Standard microscopy image deblurring algorithms like the Total Variation reg...

متن کامل

4Pi microscopy of type A with 1-photon excitation in biological fluorescence imaging.

We demonstrate that oil immersion lenses with a semi-aperture angle >/= 74 degrees enable 4Pi confocal fluorescence microscopy of type A with 1 photon excitation. The axial sidelobes amount to < 50 % of the main diffraction maximum, implying that lobe induced artifacts can be removed from the image data. The advancement reported herein enables a relative inexpensive implementation of 4Pi micros...

متن کامل

Performance Evaluation of FBP Reconstruction in SPECT Imaging

Introduction:  The  purpose  of  this  study  is  to  define  the  optimal  parameters  for  the  tomographic  reconstruction procedure in a routine single photon emission tomography. The Hoffman brain phantom  is modified to evaluate the reconstruction method. The phantom was imaged in a 3 and 2-dimensional  conformation and the results were compared.   Materials  and  Methods:  The  2D  phant...

متن کامل

Fluorescence microscopy with super-resolved optical sections.

The fluorescence microscope, especially its confocal variant, has become a standard tool in cell biology research for delivering 3D-images of intact cells. However, the resolution of any standard optical microscope is at least 3 times poorer along the axis of the lens that in its focal plane. Here, we review principles and applications of an emerging family of fluorescence microscopes, such as ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 20  شماره 

صفحات  -

تاریخ انتشار 2000