Improved treatment planning for COMS eye plaques.

نویسنده

  • Melvin A Astrahan
چکیده

PURPOSE A recent reanalysis of the Collaborative Ocular Melanoma Study (COMS) medium tumor trial concluded that incorporating factors to account for anisotropy, line source approximation, the gold plaque, and attenuation in the Silastic seed carrier into the dose calculations resulted in a significant and consistent reduction of calculated doses to structures of interest within the eye. The authors concluded that future eye plaque dosimetry should be "performed using the most up-to-date parameters available." The reason these factors are important is attributable to the low energy (125)I radiation (approximately 28 keV) that is primarily absorbed by the photoelectric process. Photoelectric absorption is quite dependent on the atomic composition of the absorbing material. Being 40% silicon by weight, the effective atomic number of Silastic is significantly greater than that of water. Although the AAPM TG43 brachytherapy formalism inherently addresses the issues of source anisotropy and geometry, its parameter that accounts for scatter and attenuation, the radial dose function g(r), assumes that the source is immersed in infinite homogeneous water. In this work, factors are proposed for (125)I that correct for attenuation in the Silastic carrier and scatter deficits resulting from the gold plaque and nearby air. The implications of using (103)Pd seeds in COMS plaques are also discussed. METHODS AND MATERIALS An existing TG43-based ophthalmic plaque planning system was modified to incorporate additional scatter and attenuation correction factors that better account for the path length of primary radiation in the Silastic seed carrier and the distance between the dose calculation point and the eye-air interface. RESULTS Compared with homogeneous water, the dose-modifying effects of the Silastic and gold are greatest near the plaque surface and immediately adjacent to the plaque, while being least near the center of the eye. The calculated dose distribution surrounding a single (125)I seed centered in a COMS 20 mm plaque was found to be consistent with previously published examples that used thermoluminescent dosimetry measurements and Monte Carlo methods. For fully loaded 12 and 20 mm plaques, calculated dose to critical ocular structures ranged from 16%-50% less than would have been reported using the standard COMS dose calculation protocol. CONCLUSIONS Treatment planning for COMS eye plaques that accurately accounts for the presence of the gold, Silastic and extraocular air is both possible and practical.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Monte Carlo Simulation for Treatment Planning Optimization of the COMS and USC Eye Plaques Using the MCNP4C Code

Introduction: Ophthalmic plaque radiotherapy using I-125 radioactive seeds in removable episcleral plaques is often used in management of ophthalmic tumors. Radioactive seeds are fixed in a gold bowl-shaped plaque and the plaque is sutured to the scleral surface corresponding to the base of the intraocular tumor. This treatment allows for a localized radiation dose delivery to the tumor with a ...

متن کامل

Dosimetric benefit of a new ophthalmic radiation plaque.

PURPOSE To determine whether the computed dosimetry of a new ophthalmic plaque, EP917, when compared with the standard Collaborative Ocular Melanoma Study (COMS) plaques, could reduce radiation exposure to vision critical structures of the eye. METHODS AND MATERIALS One hundred consecutive patients with uveal melanoma treated with COMS radiation plaques between 2007 and 2010 were included in ...

متن کامل

Dosimetry Comparison of Water Phantom and Complete Eye Definition for 125I and 103Pd Brachytherapy Plaques

Introduction: In this paper, by complete definition of human eye containing the various parts and their materials, the difference between this model and a homogeneous water phantom are compared for two ophthalmic plaques using 125I and 103Pd. Material and methods: The simulation of the two phantoms were performed in the MCNP-4C code and by using the geometry of a three-dimensional eye, differen...

متن کامل

Comparison of 16 mm OSU‐Nag and COMS eye plaques

OSU-NAG eye plaques use fewer sources than COMS-plaques of comparable size, and do not employ a Silastic seed carrier insert. Monte Carlo modeling was used to calculate 3D dose distributions for a 16 mm OSU-NAG eye plaque and a 16 mm COMS eye plaque loaded with either Iodine-125 or Cesium-131 brachytherapy sources. The OSU-NAG eye plaque was loaded with eight sources forming two squares, wherea...

متن کامل

An interactive treatment planning system for ophthalmic plaque radiotherapy.

Brachytherapy using removable episcleral plaques containing sealed radioisotope sources is being studied as an alternative to enucleation in the treatment of choroidal melanoma and other tumors of the eye. Encouraging early results have been reported, but late complications which lead to loss of vision continue to be a problem. A randomized national study, the Collaborative Ocular Melanoma Stud...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International journal of radiation oncology, biology, physics

دوره 61 4  شماره 

صفحات  -