Dynamic Magnetic Resonance Inverse Imaging using Linear Constrained Minimum Variance Beamformer

نویسندگان

  • F-H. Lin
  • M. S. Hamalainen
  • T. Witzel
  • L. L. Wald
  • J. W. Belliveau
چکیده

INTRODUCTION Inspired by the source localization methods in electroencephalography (EEG) and magnetoencephalography (MEG) [1], magnetic resonance Inverse Imaging (InI) uses a highly parallel radio-frequency coil array to solve an inverse problem in image reconstruction [2]. Due to its intrinsic ill-posed nature, InI has a non-delta point-spread function. Previously we introduced the minimum-norm estimate (MNE) reconstruction on the InI data based on the minimal L-2 norm of the source estimates. Here we propose an alternative InI reconstruction method using a linear constrained minimum variance (LCMV) beamformer, which minimizes the point-spread function of the reconstruction kernel by suppressing signal leakage from all image voxels other than the one to be reconstructed [3]. We present the LCMV InI data reconstruction algorithm and demonstrate its performance using a visual fMRI experiment with a 32-channel head array coil at 3T. We also demonstrate the improved spatial resolution of LCMV InI reconstruction compared to MNE InI reconstruction. METHODS For each image voxel to be reconstructed, the LCMV beamformer calculates a spatial filter W(ρ) to reconstruct the intensity of the voxel with index ρ by minimizing the cost function W(ρ)(D+λ C) W(ρ) with the constraint W(ρ)A(ρ’) = 1 if ρ = ρ’ and 0 otherwise. Here A is the “forward operator” consisting of the coil sensitivity profiles of the channels in the array and the aliasing operation, C is the noise covariance matrix of the array, D is the data covariance matrix, and λ is a regularization parameter. W(ρ) can be analytically derived as W(ρ) = A(ρ) (D+λ C)/ A(ρ)(D+λ C)A(ρ). Similar to the dynamic statistical parametric mapping (dSPM) used in conjunction with MNE (MNE-dSPM), LCMV beamformers can also be noise-normalized (LCMV-dSPM) to otain statistical parametric maps. The modified spatial filter is then Wdspm(ρ)= W(ρ)/sqrt(W(ρ)C W(ρ)). We demonstrated InI in an event-related visual fMRI experiment with an 8-Hz checkerboard stimulus. The experimental paradigm consisted of 6 seconds pre-stimulus baseline, followed by 2 seconds of a flashing checkerboard, and then 20 seconds fixation. A total of 40 repetitions were measured. We used a PRESTO sequence [4] to collect ultra-fast MR InI acquisitions with TE=30 ms, TR=20ms, Flip angle=20 degrees on a 3T scanner (Tim Trio, SIEMENS Medical Solutions, Erlangen, Germany) using a 32-channel head RF coil array [5]. After InI reconstruction, fMRI time courses from all channels were first detrended and subsequently averaged across repetitions to improve the SNR. The reconstructed data were also spatially smoothed by 6-mm Gaussian kernel. Using the 6 second pre-stimulus interval as the baseline and to estimate the noise covariance, we calculated the dynamic t-statistics maps in 20-ms temporal resolution. RESULTS Figure 1 shows the InI t-statistics maps of dSPM reconstructions using MNE and LCMV methods. The images were overlaid on a high-resolution Turbo-Spin-Echo (TSE) image to illustrate anatomical features. The time-series activation maps were averaged between 6 and 10 seconds after the onset of the stimulus to capture strong functional activation. Strong occipital lobe activations were observed in both reconstructions, while LCMV provided larger activation area (1335 mm) than MNE (1134 mm). The time courses from the occipital region-of-interest defined by the intersection of both MNE-dSPM and LCMV-dSPM were shown in Figure 2. We observed that both MNE-dSPM and LCMV-dSPM showed similar significant activation peaks at approximately 6 seconds after the end of the checkerboard stimulus..

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Functional magnetic resonance inverse imaging of human visuomotor systems using eigenspace linearly constrained minimum amplitude (eLCMA) beamformer

Recently proposed dynamic magnetic resonance (MR) inverse imaging (InI) is a novel parallel imaging reconstruction technique capable of improving the temporal resolution of blood-oxygen level-dependent (BOLD) contrast functional MRI (fMRI) to the order of milliseconds at the cost of moderate spatial resolution. Volumetric InI reconstructs spatial information from projection data by solving ill-...

متن کامل

B-Mode Photoacoustic Imaging using Linear Array: Numerical Study for Forward-Backward Minimum Variance Beamformer Combined with Delay-Multiply-and-Sum

Photoacoustic imaging (PAI) is a promising medical imaging modality which provides the resolution of Ultrasound (US) and the contrast of Optical imaging modalities. One of the most important challenges in PAI is image formation, especially in the case that a linear-array US transducer is used for data acquisition. This is due to the fact that in the linear-array scenario, there is only 60 degre...

متن کامل

Eigenspace Minimum L1-Norm Beamformer Reconstruction of Functional Magnetic Resonance Inverse Imaging of Visuomotor Processing

INTRODUCTION Dynamic magnetic resonance (MR) inverse imaging (InI) can improve the temporal resolution of blood oxygen level dependent (BOLD) contrasts fMRI to the order of milliseconds [1]. In InI, the spatial resolution and the source localization accuracy both critically rely on the signal-to-noise ratio (SNR) of the measurements [1]. The localization of the functional activity in ill-posed ...

متن کامل

Source-space ICA for MEG source imaging.

OBJECTIVE One of the most widely used approaches in electroencephalography/magnetoencephalography (MEG) source imaging is application of an inverse technique (such as dipole modelling or sLORETA) on the component extracted by independent component analysis (ICA) (sensor-space ICA + inverse technique). The advantage of this approach over an inverse technique alone is that it can identify and loc...

متن کامل

Minimum Variance Distortionless Response Beamforming for Tumor Segmentation in MRI 49 Minimum Variance Distortionless Response Beamforming for Tumor Segmentation in MRI

Image classification it generally requires a priori knowledge about the objects to be classified. In this paper, we present a new method to segment tumor in multispectral magnetic resonance (MR) images of the human brain. The proposed approach, called Minimum Variance Distortionless Response beamforming (MVDR) was introduced in [15] where only the knowledge of the desired signature to be classi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007