Comparison of aspiration and scintigraphic techniques for the measurement of gastric emptying rates of liquids in humans.
نویسندگان
چکیده
A comparison was made of two techniques to measure the rate of gastric emptying. A noninvasive scintigraphic technique using a gammacamera and an invasive aspiration technique based on dye dilution were performed simultaneously. Seven healthy male volunteers each consumed two different liquid meals on two separate occasions. Scintigraphic measurements were performed continuously with aspiration every 10 minutes for a total of one hour. Gastric emptying rates were expressed as slope values after semilog linearisation of the emptying curves. Agreement between the two methods was assessed from the individual differences and mean of the two techniques, as well as from the geometric mean, including 95% limits of agreement. The scintigraphic technique gave a 70% slower emptying rate than the dye dilution technique. However, the 95% limits of agreement are large (1.56 to 0.30), reflecting the small sample size and the large coefficient of variation in the techniques used.
منابع مشابه
Scintigraphic evaluation of gastric emptying after greater curvature plication in comparison with sleeve gastrectomy
Introduction: Laparoscopic gastric plication (LGP) is a relatively new restrictive bariatric procedure that emerged to avoid the problems and to reduce the cost of laparoscopic sleeve gastrectomy. In this study we present the initial short-term outcome of LGP and its effect on gastric emptying and compare it with the results of laparoscopic sleeve gastrectomy (LSG). <stro...
متن کاملScintigraphic evaluation of abomasal emptying rate in neonatal suckling lambs
Evaluation of gastric emptying rate using nuclear scintigraphy as the gold standard method has been studied in various animals, but there is no report in suckling lambs. The aim of this study was to develop a nuclear scintigraphic method to visualize and measure abomasal emptying rate by estimation of scintigraphic half emptying time (T1/2) in the live neonatal lamb. Five healthy, female Irania...
متن کاملScintigraphic measurement of gastric emptying and ultrasonographic assessment of antral area: relation to appetite.
BACKGROUND Ultrasound measurement of gastric emptying has potential advantages over scintigraphy, but there is little information about its accuracy. AIMS The relation between ultrasonographic measurements of antral area and (a) scintigraphic measurements of gastric emptying and intragastric distribution of liquids (b) postprandial satiation, were evaluated. SUBJECTS Seven normal volunteers...
متن کاملQuantitative and Qualitative Scintigraphic Measurement of Renal Function in Persian Cat Using 99mTechnetium Ethylenedicysteine and 99mTechnetium Diethylenetriaminepentaacetic
Objective- To consider the use of renal scintigraphic evaluation of kidney function in Persian cat and make a comparison between 99mTechnetium ethylenedicysteine and 99mTechnetium diethylenetriaminepentaacetic in renal scintigraphy. Design- Descriptive study Animals- 6 male healthy adult Persian cats - no clinical sign of renal disorders and prior to presentation. Proce...
متن کاملValidation of gastric-emptying scintigraphy of solids and liquids in mice using dedicated animal pinhole scintigraphy.
UNLABELLED Gastric emptying in small laboratory animals is a useful parameter to assess gastrointestinal motility for physiologic, pharmacologic, or other research purposes. In mice, phenol red recovery is considered the gold standard for determination of gastric emptying. However, this method requires sacrifice of the animal and yields data of gastric emptying at only 1 time point. Gastric-emp...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Gut
دوره 33 1 شماره
صفحات -
تاریخ انتشار 1992