Effects of electrode configuration on cochlear implant modulation detection thresholds.
نویسنده
چکیده
Cochlear implant function, as assessed by psychophysical measures, varies from one stimulation site to another within a patient's cochlea. This suggests that patient performance might be improved by selection of the best-functioning sites for the processor map. In evaluating stimulation sites for such a strategy, electrode configuration is an important variable. Variation across stimulation sites in loudness-related measures (detection thresholds and maximum comfortable loudness levels), is much larger for stimulation with bipolar electrode configurations than with monopolar configurations. The current study found that, in contrast to the loudness-related measures, magnitudes of across-site means and the across-site variances of modulation detection thresholds were not dependent on electrode configuration, suggesting that the mechanisms underlying variation in these various psychophysical measures are not all the same. The data presented here suggest that bipolar and monopolar electrode configurations are equally effective in identifying good and poor stimulation sites for modulation detection but that the across-site patterns of modulation detection thresholds are not the same for the two configurations. Therefore, it is recommended to test all stimulation sites using the patient's clinically assigned electrode configuration when performing psychophysical evaluation of a patient's modulation detection acuity to select sites for the processor map.
منابع مشابه
Cochlear-implant high pulse rate and narrow electrode configuration impair transmission of temporal information to the auditory cortex.
In the most commonly used cochlear prosthesis systems, temporal features of sound are signaled by amplitude modulation of constant-rate pulse trains. Several convincing arguments predict that speech reception should be optimized by use of pulse rates > or approximately 2,000 pulses per second (pps) and by use of intracochlear electrode configurations that produce restricted current spread (e.g....
متن کاملComment on "Temporal modulation transfer functions in patients
Shannon [I. Acoust. Soc. Am. 91, 2156-2164 (1992) ] reports a strong decrease of modulation detection thresholds with cochlear implant patients for an increase of the stimulus level. His conclusion that this result differs from the findings for acoustical stimulation in normalhearing subjects needs some clarification. His statement about acoustic stimulation is based on modulation detection mea...
متن کاملProbing the electrode-neuron interface with focused cochlear implant stimulation.
Cochlear implants are highly successful neural prostheses for persons with severe or profound hearing loss who gain little benefit from hearing aid amplification. Although implants are capable of providing important spectral and temporal cues for speech perception, performance on speech tests is variable across listeners. Psychophysical measures obtained from individual implant subjects can als...
متن کاملRelationship between Electrically Evoked Compound Action Potential Thresholds and Auditory, Language, and Speech Progress after Cochlear Implant Surgery
Introduction: Electrically evoked compound action potential (ECAP) is an objective auditory response that can be used in the programing of cochlear implants. The aims of this study were to monitor ECAP thresholds and auditory, language and speech progress for 6 months after cochlear implant surgery and to evaluate any relationship between them. Materials and Methods: Ten children with a m...
متن کاملInvestigating the Effect of Cochlear Size in Insertion of Electrode Depth in Patients with Cochlear Implantation evaluated by CT-Scan
Background Cochlear implant surgery is an invasive procedure for patients with bilateral Sensorineural hearing loss and may cause some risks such as cochlear damage. We aimed to evaluate the effectiveness of cochlear measures obtained by computed tomography (CT) scan in predicting depth of cochlear implant insertion. Materials and Methods This study was conducted in a retrospective and cross-se...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of the Acoustical Society of America
دوره 129 6 شماره
صفحات -
تاریخ انتشار 2011