An Introduction to Window Extension on Digital Flow Cytometers
ثبت نشده
چکیده
The optical detectors of a flow cytometer convert all detected light into electronic signals that are subsequently converted into digital data. A sample pulse is the electronic representation of a signal with measurable height, width, and area values. In a BD digital system, the detector output is continuously digitized, and threshold defines the signal level at which the system begins to measure a pulse within the continuous data stream. The initial window gate (WG) is the time interval during which the input signal is greater than the threshold and during which the acquisition system looks to sample a pulse. To ensure that a pulse is completely integrated, additional time, called the window extension (WE), is added before and after the initial WG to extend the total integration time. Incorrect WE settings can affect proper data acquisition and lead to incorrect data measurements. BDTM Cytometer Setup and Tracking (CS&T) is a fully automated system unique to BD digital flow cytometers that provides instrument characterization, tracking, and quality control. CS&T is a module within BD FACSDivaTM software (v6.0 and later). CS&T characterization features automatically define the instrument baseline, set correct laser delays, and fully characterize the instrument. When setting up a new cytometer configuration in CS&T, the software automatically defaults to an instrument-specific WE. For example, on the BD FACSCantoTM II cytometer, the WE defaults to a value of 7 (3.5 μs before and after the initial WG). The operator can manually set the WE to an alternate value prior to baseline determination. The appropriate WE value for a given application is specific to that application (for example, particle size and dim populations). BD FACSCantoTM clinical software, used in conjunction with BD FACSTM 7-color setup beads, provides automated cytometer setup and quality control for in vitro diagnostic (IVD) use. This system automatically sets the WE to a value of 7, which the operator cannot change. Certain BD MultitestTM reagents are designed for use with this software system. Use of certain BD products on an instrument with different software that might have different settings, including but not limited to WE, might alter the results. In summary, the manipulation of WE in conjunction with the use of BD FACSDiva software’s CS&T performance checks allows an operator to optimize cytometer settings for a given application. However, certain BD products must be used with a WE of 7. If an operator chooses to perform these tests using a different WE (or other setting), the application must be fully validated prior to use.
منابع مشابه
Development of A Sliding Window Protocol for Data Synchronization in a Flow Cytometer
Flow cytometers are instruments for analyzing blood cells individually and have been widely used for clinical diagnostics and research discovery. A flow cytometer is able to acquire signals of several independent physical or chemical parameters of each cell altogether. Therefore, synchronization of data acquisition among all parameters of each cell is required for a reliable flow cytometer. Mos...
متن کاملEnergy window setting for optimum Tl-201 cardiac imaging [Persian]
Introduction: Poor sensitivity and poor signal to noise ratio because of low injected thallium dose and presence of scattered photons are the main problems in using thallium in scintigraphic imaging of the heart. Scattered photons are the main cause of degrading the contrast and resolution in SPECT imaging that result in error in quantification. Thallium decay is ve...
متن کاملHydraulic Network Modeling to Analyze Stream Flow Effectiveness on Heat Transfer Performance of Shell and Tube Heat Exchangers
In this article, stream flow effectivness is based on hydraulic network studied in the shell-side of a shell and tube heat exchange as a case study. For an appropriate heat exchangers rating design to meet a specified duty, it's better to consider each stream flow separately. Using the hydraulic network principals, a set of the correlations for calculating different stream flow rates in the cro...
متن کاملImaging Cells in Flow Cytometer Using Spatial-Temporal Transformation
Flow cytometers measure fluorescence and light scattering and analyze multiple physical characteristics of a large population of single cells as cells flow in a fluid stream through an excitation light beam. Although flow cytometers have massive statistical power due to their single cell resolution and high throughput, they produce no information about cell morphology or spatial resolution offe...
متن کاملScheduling of Multiple Autonomous Guided Vehicles for an Assembly Line Using Minimum Cost Network Flow
This paper proposed a parallel automated assembly line system to produce multiple products having multiple autonomous guided vehicles (AGVs). Several assembly lines are configured to produce multiple products in which the technologies of machines are shared among the assembly lines when required. The transportation between the stations in an assembly line (intra assembly line) and among station...
متن کامل