Simultaneous determination of procymidone, pyridaben and beta-cypermethrin residues in tea solution by GC-ECD.

نویسندگان

  • Changpeng Zhang
  • Hua Zhao
  • Min Wu
  • Xiuqing Hu
  • Xiaoming Cai
  • Lifeng Ping
  • Zhen Li
چکیده

A sensitive and effective method for the simultaneous quantitative determination of procymidone, pyridaben and beta-cypermethrin residues in tea solutions was developed and validated using a gas chromatograph (GC) equipped with an electron capture detector (ECD). The analysis of the three pesticides in tea solutions involved extraction with petroleum ether-ethyl acetate (3:1, v/v), cleanup using a Florisil solid-phase extraction cartridge and subsequent determination by GC-ECD. Recovery studies were carried out at three spiked levels (0.05, 0.1 and 0.5 mg/kg). The overall average recoveries using this method in green teas and black teas at the three concentration levels ranged from 85.63 to 105.80% with relative standard deviations in the range of 1.29-4.97% (n = 5) for all analytes. The quantification limits of procymidone, pyridaben and beta-cypermethrin were 0.025, 0.038 and 0.030 mg/kg, respectively, which were lower than the maximum residue limits (MRLs) of 0.1 mg/kg procymidone, 0.05 mg/kg pyridaben and 0.5 mg/kg beta-cypermethrin in tea samples established by European Union legislations. This study provides a theoretical basis for China to draw up MRLs for procymidone, pyridaben and beta-cypermethrin in tea solutions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development of a SPME-GC-ECD methodology for selected pesticides in must and wine samples.

A method for the determination of some pesticide residues in must and wine samples was developed using solid-phase microextraction (SPME) and gas chromatography-electron capture detection (GC/ECD). The procedure only needs dilution as sample pre-treatment and is therefore simple, fast and solvent-free. Eight fungicides (vinclozolin, procymidone, iprodione, penconazole, fenarimol, folpet, nuarim...

متن کامل

Determination of Pyrethroid Residues in Meat by Gas Chromatography with Electron Capture Detection

The method for simultaneous determination of residues of seven pyrethroids (bifenthrin, cyfluthrin, lambda-cyhalothrin, cypermethrin, deltamethrin, fenvalerate and permethrin) in animal meat samples has been developed and validated. The method is based on the extraction of pyrethroid residues with mixture of acetone-petroleum ether, freezing step, clean-up on a Florisil column, and finally dete...

متن کامل

[Investigation of pesticide residues in foods distributed in Kitakyushu City].

We investigated 160 kinds of pesticide residues in 715 samples of 116 kinds of foods distributed in Kitakyushu city. Sixty kinds of pesticides were detected in 55 kinds of foods (204 samples) in the range of 0.002-22 mg/kg. Five kinds of pesticides in 7 samples violated the residue standards and the indication of "unused". The detection ratios of unregulated pesticide in domestic and imported f...

متن کامل

Simultaneous Determination of 17 Pesticide Residues in Rice by GC/MS using a Direct Sample Introduction Procedure and Spiked Calibration Curves

A reliable, rapid and accurate method based on spiked calibration curves and direct sample introduction was developed for determination of 17 pesticide residues in rice by gas chromatography-mass spectrometry single quadrupole selected ion monitoring GC/MS-SQ-SIM. Sample preparation is based on extraction with acetonitrile without clean up. The use of spiked calibration curves for constructing...

متن کامل

Simultaneous Determination of 17 Pesticide Residues in Rice by GC/MS using a Direct Sample Introduction Procedure and Spiked Calibration Curves

A reliable, rapid and accurate method based on spiked calibration curves and direct sample introduction was developed for determination of 17 pesticide residues in rice by gas chromatography-mass spectrometry single quadrupole selected ion monitoring GC/MS-SQ-SIM. Sample preparation is based on extraction with acetonitrile without clean up. The use of spiked calibration curves for constructing...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of chromatographic science

دوره 50 10  شماره 

صفحات  -

تاریخ انتشار 2012