Automated bone marrow analysis using the CD4000 automated haematology analyser

نویسندگان

  • Ryousuke Yamamura
  • Takahisa Yamane
  • Masayuki Hino
  • Kensuke Ohta
  • Ki-Ryang Koh
  • Izumi Tsuda
  • Takayuki Takubo
  • Noriyuki Tatsumi
چکیده

At present, bone marrow analysis is performed microscopically, but is time consuming and labour intensive. No automated methods have been successfully applied to classification of bone marrows cells because automated blood cell analysers have been incapable of identifying erythroblasts. The present study was designed to evaluate automated analysis of bone marrow aspirates with the CELL-DYN 4000 (CD4000) haematology analyser, which enables automated determination of erythroblast counts in both the normal mode (haemolytic time; 11.5 s) and the resistant RBC mode (34.0 s). The percentages of subpopulations including lymphocytes, neutrophils and erythroblasts were obtained with the CD4000, and as a reference, differential counts by microscopic observation of May-Grünwald-Giesa-stained films of bone marrow aspirates were performed (n=98). Significant correlations (P < 0.01) between the results obtained with the two methods were observed for total nucleated cell count and lymphocytes, neutrophils, erythroblasts and myeloid/erythroid (M/E) ratio. However, there were biases in the average percentages of erythroblasts, lymphocytes and M/E ratio obtained using the normal mode with the CD4000 toward values lower than those obtained with the microscopic method. Using the RBC resistant mode with the CD4000, the average percentages of erythroblasts, lymphocytes and M/E ratio approximated those obtained with the microscopic method. In conclusion, the CD4000 in resistant RBC mode is more useful for analysis of bone marrow aspirates than is the normal mode, because the former better approximates the M/E ratio than the latter.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

First basic performance evaluation of the XE-2100 haematology analyser

The newly developed XE-2100 haematology analyser can provide complete blood counts, leukocyte differentials, perform reticulocyte analysis, and obtain quantitative data on nucleated red blood cells (NRBCs). In this study, we evaluated the basic performance of this instrument using routinely obtained blood specimens treated with ethylenediaminetetraacetic acid-2K. Reproducibility, carryover, sta...

متن کامل

Evaluation of use of the optional unit QA-810V for the determination of five-part leukocyte differentials

The newly developed QA-810V is an optional unit for the determination of five-part white blood cell differentials. It can be used together with the same manufacturer's haematology analyser which has been used in relatively small-sized laboratories. The present study evaluates the basic performance of the QA-810 V and the MEK-8118 haematology analyser using routinely obtained blood specimens tre...

متن کامل

[A new automated haematology analyser: the Excell 2280].

Excell 2280 analyser is a new automated haematology analyser manufactured by Drew Scientific Inc, Texas, USA, and distributed in France by MAXMAT S.A., Montpellier. It can achieve 80 complete blood cell counts per hour, with leukocyte differential counts. Three sampling possibilities are included: a direct one (open tubes, 180 microL), a blood saver one (80 microL) and an automatic, through-the...

متن کامل

Automated Bone Marrow Analysis : Dream or Reality?

Since 1997, the availability, in haematology laboratories of automated analyzers capable of performing an extended differential blood cell count, including the nucleated red blood cell (NRBC) count, allowed their experimental use to estimate the cell composition of bone marrow fluid. In 1999 we evaluated the Sysmex XE-2100 to detect the clinical usefulness of immature granulocyte (IG) and NRBC ...

متن کامل

Automated counting of white blood cells in synovial fluid.

OBJECTIVES To evaluate the performance of automated leucocyte (white blood cell; WBC) counting by comparison with manual counting. METHODS The number of WBC was determined in heparinized synovial fluid samples by the use of (i) a standard urine cytometer (Kova) and a microscope (reference method) and (ii) a haematology analyser (Sysmex XE-2100; WBC/BASO and DIFF channels). Imprecision within ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of Automated Methods and Management in Chemistry

دوره 22  شماره 

صفحات  -

تاریخ انتشار 2000