Immobilizing enzymes onto electrode arrays by hydrogel photolithography to fabricate multi-analyte electrochemical biosensors.
نویسندگان
چکیده
This paper describes a biomaterial microfabrication approach for interfacing functional biomolecules (enzymes) with electrode arrays. Poly (ethylene glycol) (PEG) hydrogel photopatterning was employed to integrate gold electrode arrays with the enzymes glucose oxidase (GOX) and lactate oxidase (LOX). In this process, PEG diacrylate (DA)-based prepolymer containing enzyme molecules as well as redox species (vinylferrocene) was spin-coated, registered, and UV cross-linked on top of an array of gold electrodes. As a result, enzyme-carrying circular hydrogel structures (600 microm diameter) were fabricated on top of 300 microm diameter gold electrodes. Importantly, when used with multiple masks, hydrogel photolithography allowed us to immobilize GOX and LOX molecules on adjacent electrodes within the same electrode array. Cyclic voltammetry and amperometry were used to characterize biosensor electrode arrays. The response of the biosensor array was linear for up to 20 mM glucose with sensitivity of 0.9 microA cm(-2) mM(-1) and 10 mM lactate with sensitivity of 1.1 microA cm(-2) mM(-1). Importantly, simultaneous detection of glucose and lactate from the same electrode array was demonstrated. A novel strategy for integrating biological and electrical components of a biosensor described in this paper provides the flexibility to spatially resolve and register different biorecognition elements with individual members of a miniature electrode array. Of particular interest to us are future applications of these miniature electrodes for real-time monitoring of metabolite fluxes in the vicinity of living cells.
منابع مشابه
Electrochemical Aptamer-Based Biosensors: Recent Advances and Perspectives
This paper reviews the advancements of a wide range of electrochemical aptamer-based biosensors, electrochemical aptasensors, for target analytes monitoring. Methods for immobilizing aptamers onto an electrode surface are discussed. Aptasensors are presented according to their detection strategies. Many of these are simply electrochemical, aptamer-based equivalents of traditional immunochemical...
متن کاملAn Electrochemical Interface for Integrated Biosensors
This paper presents an integrated, protein-based, biosensor that can be scaled to form high-density, multi-analyte sensor arrays physically integrated on a signal conditioning circuit die. A fully scalable, post-CMOS-compatible, threeelectrode interface to biochemical sensors has been developed. A silicon substrate electrode system, consisting of Ti/Au working and auxiliary electrodes and a Ti/...
متن کاملMicrofluidic biosensor based on an array of hydrogel-entrapped enzymes.
Here we show that a microfluidic sensor based on an array of hydrogel-entrapped enzymes can be used to simultaneously detect different concentrations of the same analyte (glucose) or multiple analytes (glucose and galactose) in real time. The concentration of paraoxon, an acetylcholine esterase inhibitor, can be quantified using the same approach. The hydrogel micropatch arrays and the microflu...
متن کاملMicropatterned Nanocomposite Hydrogels for Biosensing Applications
This paper describes the use of Au nanoparticle (NP)-containing hydrogel microstructures in the development of electrochemical enzyme-based biosensors. To fabricate biosensors, AuNPs were conjugated with glucose oxidase (GOX) or horseradish peroxidase (HRP) molecules and were dispersed in the prepolymer solution of poly(ethylene glycol) diacrylate (PEG-DA). Vinylferrocene (VF) was also added in...
متن کاملLarge-area interdigitated array microelectrodes for electrochemical sensing
Advanced photolithography developed for the semiconductor industry has been used to fabricate interdigitated microelectrode arrays that pass steady-state limiting currents of up to 230 nArmM analyte — 2.5 times more than the most sensitive interdigitated array built to date, and exhibit response times of ;5 ms. This performance results from the small interelectrode gap and the large active area...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- ACS applied materials & interfaces
دوره 2 3 شماره
صفحات -
تاریخ انتشار 2010