Jet expansion module for liquid-sampled GC-discharge ionization detection of liquefied gases.
نویسندگان
چکیده
A rugged jet expansion module was designed, built, and utilized to sample liquefied gas for gas chromatography-discharge ionization detector (GC-DID) analysis. The module is inserted at an intermediate stage between a higher pressure sample cylinder and lower pressure gas injection manifold. The title jet module permits selection of liquid-phase or vapor-phase sampling by setting the valve-cylinder orientation up or down (relative to gravity). It consists of a four-way stainless steel cross, plus the following components connected to pipe thread ports: (1) mechanical pressure gauge, -15 to +30 psig; (2) threaded nut with 0.010-in. jet orifice (connect to sample cylinder valve); (3) bellows valve (connect to GC manifold); (4) bellows valve (connect to expansion cylinder). Making use of the jet module, measurement of air concentration in [15N]ammonia and sulfur hexafluoride (single-component) samples was found to be significantly lower in the liquid phase by GC-DID. This compact apparatus enables phase-selective sampling, reduces primary manifold contamination, and improves operator safety.
منابع مشابه
Determination of valproic acid in human plasma using dispersive liquid-liquid microextraction followed by gas chromatography-flame ionization detection
Objective(s): Dispersive liquid-liquid microextraction coupled with gas chromatography (GC)-flame ionization detector was developed for the determination of valproic acid (VPA) in human plasma. Materials and Methods: Using a syringe, a mixture of suitable extraction solvent (40 µl chloroform) and disperser (1 ml acetone) was quickly added to 10 ml of diluted plasma sample containing VPA (pH, 1....
متن کاملDetermination of 2-phenylethanol in Rose Water Using Dispersive Liquid-Liquid Microextraction with Gas Chromatography Flame Ionization Detection
A simple and rapid microextraction procedure based on dispersive liquid-liquid microextraction (DLLME) coupled with gas chromatography-flame ionization detection (GC-FID) was developed for the extraction and analysis of 2-phenylethanol in rose water sample. In the proposed approach, carbon tetrachloride and ethanol were used as extraction and dispersive solvents, respectively. Some important pa...
متن کاملScreening Method for Mononitrotoluenes in Natural Waters Using Magnetic Solvent Bar Liquid-Phase Micro-extraction Followed by Gas Chromatography-Flame Ionization Detection
A simple andefficient hollow fiber-based method,viz magnetic solvent bar liquid-phasemicroextraction (MSB-LPME) combined with gas chromatography-flame ionization detection (GCFID)has been successfully developed for the trace determination of mononitrotoluenes (MNTs) innatural water samples. The analytes were extracted from sample solution to the organic solventimmobilize...
متن کاملResidue analysis of 500 high priority pesticides: better by GC-MS or LC-MS/MS?
This overview evaluates the capabilities of mass spectrometry (MS) in combination with gas chromatography (GC) and liquid chromatography (LC) for the determination of a multitude of pesticides. The selection of pesticides for this assessment is based on the status of production, the existence of regulations on maximum residue levels in food, and the frequency of residue detection. GC-MS with el...
متن کاملDetermination of Phenol and Carvacrol in Honey Samples Using Dispersive Liquid-Liquid Microextraction and Experimental Design for Optimization
A very simple, rapid and sensitive dispersive liquid-liquid microextraction (DLLME) followed by gas chromatography and flame ionization detection (GC-FID) was developed for the determination of phenol and carvacrol in honey samples. A mixture of 100 µl dichloromethane (extraction solvent) and 0.5 ml acetonitrile (disperser solvent) was rapidly injected into sample solution. Thereby a cloudy sol...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical chemistry
دوره 75 5 شماره
صفحات -
تاریخ انتشار 2003