Redo aortic valve surgery: Influence of prosthetic valve endocarditis on outcomes.

نویسندگان

  • Sergey Leontyev
  • Michael A Borger
  • Paul Modi
  • Sven Lehmann
  • Jörg Seeburger
  • Thomas Walther
  • Friedrich W Mohr
چکیده

OBJECTIVE Compared with reoperative aortic valve replacement for nonendocarditic causes, the contemporary risk and long-term outcomes of reoperation for aortic prosthetic valve endocarditis are ill-defined. METHODS Between December 1994 and April 2008, 313 patients underwent reoperative aortic valve replacement, of whom 152 (48.6%) had prosthetic valve endocarditis. Mean follow-up was 6.5 ± 0.4 years and 97.4% complete. RESULTS Patients with prosthetic valve endocarditis were older with a higher risk profile. The overall hospital mortality was 15.3% (n = 48) (prosthetic valve endocarditis vs nonendocarditis: 24.3%, n = 37, vs 6.8%, n = 11; P < .001). Independent predictors of perioperative mortality for prosthetic valve endocarditis were sepsis (odds ratio [OR], 6.5; 95% confidence interval [CI], 2.0-21.0; P < .01), ejection fraction less than 30% (OR, 5.8; 95% CI, 1.3-25.0; P = .02), concomitant coronary artery bypass grafting (OR, 3.3; 95% CI, 1.1-9.8; P = .03), and aortic root abscess (OR, 2.7; 95% CI, 1.2-6.4; P = .02), and for the nonendocarditis group were concomitant coronary artery bypass grafting (OR, 8.1; 95% CI, 2.0-33.0; P < .01), and mitral valve surgery (OR, 4.8; 95% CI, 1.3-17.9; P = .02). The 1-, 3-, 5-, and 10-year survivals for patients with and without prosthetic valve endocarditis were 52% ± 4% versus 82% ± 3%, 43% ± 5% versus 73% ± 4%, 37% ± 5% versus 63% ± 5%, and 31% ± 7% versus 56% ± 8%, respectively (log rank < 0.001). Predictors of long-term mortality in prosthetic valve endocarditis were sepsis (OR, 3.1; 95% CI, 1.5-4.5; P < .01) and unstable preoperative status (OR, 1.8; 95% CI, 1.2-3.5; P = .04), whereas in nonendocarditis patients the only predictor was New York Heart Association class IV (OR, 2.5; 95% CI, 2.8-7.4; P < .01). Five-year actuarial freedom from endocarditis was 80% ± 0.3% versus 95% ± 0.6% (prosthetic valve endocarditis cersus nonendocarditis; P = .002). CONCLUSIONS Despite contemporary therapy, reoperation for aortic prosthetic valve endocarditis is still associated with relatively high perioperative mortality and limited long-term survival.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A rare case of prosthetic aortic valve endocarditis complicated with multiple fistula to peri aortic structure

  Multiple aorto-cardiac cavity communications is very rare but important complication of prosthetic aortic valve endocarditis. The case below illustrates multiple aorto-cardiac cavity fistula formation following prostethic aortic valve endocarditis presented with slowly progressive symptoms of heart failure. A brief review of surgical reconstruction and the existing literature are presented, i...

متن کامل

Treatment of prosthetic valve endocarditis complicated by destruction of the aortic annulus.

PURPOSE It has been reported that surgical treatment for prosthetic valve endocarditis complicated by destruction of the aortic annulus is associated with high mortality and morbidity. The aim of this study was to evaluate the efficacy of our surgical strategy for this situation. METHODS Between October 2003 and April 2009, eight patients (mean age 68.6 years) with prosthetic valve endocardit...

متن کامل

Valve-in-Valve Replacement Using a Sutureless Aortic Valve

BACKGROUND We present a unique case of a 61-year-old female patient with homograft deterioration after redo surgery for prosthetic valve endocarditis with root abscess. CASE REPORT The first operation was performed for type A dissection with root, arch, and elephant trunk replacement of the thoracic aorta. The present re-redo surgery was performed as valve-in-valve with a sutureless aortic biop...

متن کامل

Prosthetic valve endocarditis caused by multidrug-resistant Candida albicans in a patient with myelodysplasia syndrome: A case report and literature review

Background and Purpose: Candida endocarditis is an infrequent disease with a high mortality rate, which commonly occurs in immunosuppressed patients with cardiac valve replacement. We reported a 70-year-old woman diagnosed with Candida prosthetic valve endocarditis (PVE). This study also involved a review of all published cases of Candida PVE from 1970. Case report: Herein, we reported a 70-ye...

متن کامل

Chronic encapsulated mediastinal abscess presenting with remote cutaneous fistulization 12 years after redo aortic valve replacement for prosthetic valve endocarditis

Chronic encapsulated mediastinal abscess is an unusual complication of previous open heart surgery. We report on the case of a 79 year old male who presented with epigastric fistulization of an encapsulated anterior mediastinal abscess 12 years after a redo aortic valve replacement for prosthetic valve endocarditis. The encapsulated abscess and its complex branching tracts and the cutaneous fis...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of thoracic and cardiovascular surgery

دوره 142 1  شماره 

صفحات  -

تاریخ انتشار 2011